	<title>Asenware Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<atom:link href="https://www.cityfireservice.com/brand/asenware/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cityfireservice.com/brand/asenware/</link>
	<description></description>
	<lastBuildDate>Tue, 24 Mar 2026 08:15:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.cityfireservice.com/wp-content/uploads/2022/11/cropped-default-logo-32x32.png</url>
	<title>Asenware Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<link>https://www.cityfireservice.com/brand/asenware/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Conventional UV 4 wire Flame Detector Asenware</title>
		<link>https://www.cityfireservice.com/shop/flame-detector-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=flame-detector-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Sep 2024 12:28:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4187</guid>

					<description><![CDATA[<div class="brief">This Asenware UV flame detector uses the best flame sensor. It has a sensitive response and large detection angle, and it is consistent and long-term stable and reliable. The red LED indicators on the flame detector provide local 360° visual alarm indication. They flash every 5 seconds to indicate the detector is on and is working. When a flame is detected, the fire alarm will be triggered, the red LED indicator will be on, and the buzzer will make a loud alarm sound.</div>
<p>The post <a href="https://www.cityfireservice.com/shop/flame-detector-asenware/">Conventional UV 4 wire Flame Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 data-start="219" data-end="258"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 4-Wire Conventional UV Flame Detector – AW-D146R</h4>
<hr data-start="315" data-end="318" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="347" data-end="649">The Asenware AW-D146R UV Flame Detector is equipped with a high-quality flame sensor, offering fast response, wide detection angle, and long-term reliability. Its 360° red LED indicator provides clear local alarm signals, while the built-in buzzer ensures an unmistakable audible warning.</p>
<p data-start="651" data-end="876">With its test button for quick verification and reset, the AW-D146R combines user-friendly operation with advanced safety performance, making it suitable for residential, commercial, and industrial applications.</p>
<hr data-start="878" data-end="881" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="904" data-end="1287">
<li data-start="904" data-end="949">
<p data-start="906" data-end="949"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Easy installation with mounting bracket</p>
</li>
<li data-start="950" data-end="995">
<p data-start="952" data-end="995"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Highly sensitive &amp; durable flame sensor</p>
</li>
<li data-start="996" data-end="1028">
<p data-start="998" data-end="1028"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Loud alarm sound &gt;85dB @3m</p>
</li>
<li data-start="1029" data-end="1076">
<p data-start="1031" data-end="1076"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Local 360° visual LED alarm indicator</p>
</li>
<li data-start="1077" data-end="1116">
<p data-start="1079" data-end="1116"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Excellent reliability &amp; stability</p>
</li>
<li data-start="1117" data-end="1173">
<p data-start="1119" data-end="1173"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Compact, neat appearance with wide detection angle</p>
</li>
<li data-start="1174" data-end="1228">
<p data-start="1176" data-end="1228"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Complies with EN54-10 international standard</p>
</li>
<li data-start="1229" data-end="1287">
<p data-start="1231" data-end="1287"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Ideal for homes, offices &amp; flame detection areas</p>
</li>
</ul>
<hr data-start="1289" data-end="1292" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1329" data-end="1892">
<thead data-start="1329" data-end="1350">
<tr data-start="1329" data-end="1350">
<th data-start="1329" data-end="1341" data-col-size="sm">Parameter</th>
<th data-start="1341" data-end="1350" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1373" data-end="1892">
<tr data-start="1373" data-end="1410">
<td data-start="1373" data-end="1397" data-col-size="sm"><strong data-start="1375" data-end="1396">Operating Voltage</strong></td>
<td data-start="1397" data-end="1410" data-col-size="sm">DC 12–28V</td>
</tr>
<tr data-start="1411" data-end="1467">
<td data-start="1411" data-end="1435" data-col-size="sm"><strong data-start="1413" data-end="1434">Operating Current</strong></td>
<td data-start="1435" data-end="1467" data-col-size="sm">Monitoring ≤3mA, Alarm ≤30mA</td>
</tr>
<tr data-start="1468" data-end="1496">
<td data-start="1468" data-end="1483" data-col-size="sm"><strong data-start="1470" data-end="1482">Spectrum</strong></td>
<td data-start="1483" data-end="1496" data-col-size="sm">185–260nm</td>
</tr>
<tr data-start="1497" data-end="1526">
<td data-start="1497" data-end="1515" data-col-size="sm"><strong data-start="1499" data-end="1514">Sensitivity</strong></td>
<td data-start="1515" data-end="1526" data-col-size="sm">Grade 1</td>
</tr>
<tr data-start="1527" data-end="1558">
<td data-start="1527" data-end="1549" data-col-size="sm"><strong data-start="1529" data-end="1548">Detection Angle</strong></td>
<td data-start="1549" data-end="1558" data-col-size="sm">≤120°</td>
</tr>
<tr data-start="1559" data-end="1602">
<td data-start="1559" data-end="1588" data-col-size="sm"><strong data-start="1561" data-end="1587">Relay Contact Capacity</strong></td>
<td data-start="1588" data-end="1602" data-col-size="sm">1A @ DC24V</td>
</tr>
<tr data-start="1603" data-end="1641">
<td data-start="1603" data-end="1627" data-col-size="sm"><strong data-start="1605" data-end="1626">Alarm Sound Level</strong></td>
<td data-start="1627" data-end="1641" data-col-size="sm">≥85dB @ 3m</td>
</tr>
<tr data-start="1642" data-end="1719">
<td data-start="1642" data-end="1675" data-col-size="sm"><strong data-start="1644" data-end="1674">Operating Temp. &amp; Humidity</strong></td>
<td data-start="1675" data-end="1719" data-col-size="sm">–10°C to +55°C, ≤95% RH (non-condensing)</td>
</tr>
<tr data-start="1720" data-end="1757">
<td data-start="1720" data-end="1738" data-col-size="sm"><strong data-start="1722" data-end="1737">Application</strong></td>
<td data-start="1738" data-end="1757" data-col-size="sm">Indoor use only</td>
</tr>
<tr data-start="1758" data-end="1795">
<td data-start="1758" data-end="1784" data-col-size="sm"><strong data-start="1760" data-end="1783">Compliance Standard</strong></td>
<td data-start="1784" data-end="1795" data-col-size="sm">EN54-10</td>
</tr>
<tr data-start="1796" data-end="1833">
<td data-start="1796" data-end="1819" data-col-size="sm"><strong data-start="1798" data-end="1818">Material &amp; Color</strong></td>
<td data-start="1819" data-end="1833" data-col-size="sm">ABS, White</td>
</tr>
<tr data-start="1834" data-end="1869">
<td data-start="1834" data-end="1851" data-col-size="sm"><strong data-start="1836" data-end="1850">Dimensions</strong></td>
<td data-start="1851" data-end="1869" data-col-size="sm">Ø99.8 × 43.2mm</td>
</tr>
<tr data-start="1870" data-end="1892">
<td data-start="1870" data-end="1883" data-col-size="sm"><strong data-start="1872" data-end="1882">Weight</strong></td>
<td data-start="1883" data-end="1892" data-col-size="sm">~120g</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p data-start="1921" data-end="2068"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Buildings<br data-start="1945" data-end="1948" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Offices &amp; Commercial Facilities<br data-start="1982" data-end="1985" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Workshops<br data-start="2008" data-end="2011" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Hospitals<br data-start="2033" data-end="2036" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4e6.png" alt="📦" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Warehouses &amp; Indoor Storage</p>
<p>The post <a href="https://www.cityfireservice.com/shop/flame-detector-asenware/">Conventional UV 4 wire Flame Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Extinguishing Panel Asenware</title>
		<link>https://www.cityfireservice.com/shop/extinguishing-panel-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=extinguishing-panel-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 10:50:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4163</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">
<div class="name">
<div class="name"><strong>Automatic Gas Extinguisher Control Panel AW-GEC2169</strong></div>
<div></div>
<div class="brief">AW-GEC2169 with a new design, easy to operate, metal box opening and closing door with visible glass window, make the Panel running more safe, The automatic extinguisher control panel AW-GEC2169 is designed execute European standards of EN54-2 and EN54-4 F...</div>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/extinguishing-panel-asenware/">Extinguishing Panel Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<h4 data-start="194" data-end="258"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Automatic Gas Extinguisher Control Panel</h4>
<h6 data-start="259" data-end="284"><strong>Model: AW-GEC2169</strong></h6>
<hr data-start="286" data-end="289" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="318" data-end="425">The <strong data-start="322" data-end="345">Asenware AW-GEC2169</strong> Automatic Gas Fire Extinguisher Control Panel is designed in compliance with:</p>
<ul data-start="427" data-end="685">
<li data-start="427" data-end="513">
<p data-start="429" data-end="513"><strong data-start="429" data-end="439">EN54-2</strong>: Fire detection and fire alarm systems – Control &amp; Indicating Equipment</p>
</li>
<li data-start="514" data-end="592">
<p data-start="516" data-end="592"><strong data-start="516" data-end="526">EN54-4</strong>: Fire detection and fire alarm systems – Power Supply Equipment</p>
</li>
<li data-start="593" data-end="685">
<p data-start="595" data-end="685"><strong data-start="595" data-end="608">EN12094-1</strong>: Fixed firefighting systems – Electrical automatic control &amp; delay devices</p>
</li>
</ul>
<p data-start="687" data-end="850">With a modern metal enclosure, glass viewing window, and user-friendly interface, the AW-GEC2169 ensures safe, stable, and reliable firefighting control.</p>
<hr data-start="852" data-end="855" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Features</strong></p>
<ul data-start="882" data-end="1628">
<li data-start="882" data-end="963">
<p data-start="884" data-end="963"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Dual Zone Inputs – Two alarm zone signals, up to 16 detectors per zone</p>
</li>
<li data-start="964" data-end="1031">
<p data-start="966" data-end="1031"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> EM Valve Output – Controls electromagnetic valve release</p>
</li>
<li data-start="1032" data-end="1114">
<p data-start="1034" data-end="1114"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Multiple Panel Outputs – Line fault, alarm, extinguishing signal, 24VDC</p>
</li>
<li data-start="1115" data-end="1188">
<p data-start="1117" data-end="1188"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Automatic Power Switching – Between AC 220V and backup battery</p>
</li>
<li data-start="1189" data-end="1251">
<p data-start="1191" data-end="1251"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Three Access Levels – View, operation, and settings</p>
</li>
<li data-start="1252" data-end="1336">
<p data-start="1254" data-end="1336"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Real-Time Fault Detection – Input, output, power, ground, fuse monitoring</p>
</li>
<li data-start="1337" data-end="1413">
<p data-start="1339" data-end="1413"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Manual Functions – Disable zones, evacuate, silence alarms, reset</p>
</li>
<li data-start="1414" data-end="1489">
<p data-start="1416" data-end="1489"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Delay Time Settings – Adjustable release and reset delay (0–60s)</p>
</li>
<li data-start="1490" data-end="1550">
<p data-start="1492" data-end="1550"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Secure Metal Cabinet – Lockable with glass window</p>
</li>
<li data-start="1551" data-end="1628">
<p data-start="1553" data-end="1628"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Long-Term Stability – Rigorous factory testing ensures reliability</p>
</li>
</ul>
<hr data-start="1630" data-end="1633" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1670" data-end="2907">
<thead data-start="1670" data-end="1699">
<tr data-start="1670" data-end="1699">
<th data-start="1670" data-end="1682" data-col-size="sm">Parameter</th>
<th data-start="1682" data-end="1699" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1730" data-end="2907">
<tr data-start="1730" data-end="1775">
<td data-start="1730" data-end="1745" data-col-size="sm"><strong data-start="1732" data-end="1744">AC Input</strong></td>
<td data-start="1745" data-end="1775" data-col-size="md">220VAC, 50Hz (+10% / –15%)</td>
</tr>
<tr data-start="1776" data-end="1828">
<td data-start="1776" data-end="1792" data-col-size="sm"><strong data-start="1778" data-end="1791">DC Output</strong></td>
<td data-start="1792" data-end="1828" data-col-size="md">24VDC (19–28V) &amp; 5VDC (4.9–5.1V)</td>
</tr>
<tr data-start="1829" data-end="1861">
<td data-start="1829" data-end="1851" data-col-size="sm"><strong data-start="1831" data-end="1850">Standby Current</strong></td>
<td data-start="1851" data-end="1861" data-col-size="md">&lt;450mA</td>
</tr>
<tr data-start="1862" data-end="1911">
<td data-start="1862" data-end="1903" data-col-size="sm"><strong data-start="1864" data-end="1902">Max Current (Excl. Battery Charge)</strong></td>
<td data-start="1903" data-end="1911" data-col-size="md">1.4A</td>
</tr>
<tr data-start="1912" data-end="1966">
<td data-start="1912" data-end="1934" data-col-size="sm"><strong data-start="1914" data-end="1933">Battery Current</strong></td>
<td data-start="1934" data-end="1966" data-col-size="md">1.85A (max, current-limited)</td>
</tr>
<tr data-start="1967" data-end="2012">
<td data-start="1967" data-end="1990" data-col-size="sm"><strong data-start="1969" data-end="1989">Auxiliary Output</strong></td>
<td data-start="1990" data-end="2012" data-col-size="md">24VDC, 200mA (max)</td>
</tr>
<tr data-start="2013" data-end="2069">
<td data-start="2013" data-end="2038" data-col-size="sm"><strong data-start="2015" data-end="2037">Release Delay Time</strong></td>
<td data-start="2038" data-end="2069" data-col-size="md">0–60s adjustable (5s steps)</td>
</tr>
<tr data-start="2070" data-end="2125">
<td data-start="2070" data-end="2089" data-col-size="sm"><strong data-start="2072" data-end="2088">Battery Type</strong></td>
<td data-start="2089" data-end="2125" data-col-size="md">2 × 12V / 2.3Ah sealed lead-acid</td>
</tr>
<tr data-start="2126" data-end="2162">
<td data-start="2126" data-end="2155" data-col-size="sm"><strong data-start="2128" data-end="2154">Low-Voltage Protection</strong></td>
<td data-start="2155" data-end="2162" data-col-size="md">21V</td>
</tr>
<tr data-start="2163" data-end="2198">
<td data-start="2163" data-end="2192" data-col-size="sm"><strong data-start="2165" data-end="2191">Max Detectors per Zone</strong></td>
<td data-start="2192" data-end="2198" data-col-size="md">16</td>
</tr>
<tr data-start="2199" data-end="2247">
<td data-start="2199" data-end="2222" data-col-size="sm"><strong data-start="2201" data-end="2221">Total CIE Points</strong></td>
<td data-start="2222" data-end="2247" data-col-size="md">32 (detectors + MCPs)</td>
</tr>
<tr data-start="2248" data-end="2299">
<td data-start="2248" data-end="2273" data-col-size="sm"><strong data-start="2250" data-end="2272">Zone Alarm Current</strong></td>
<td data-start="2273" data-end="2299" data-col-size="md">6mA (min) / 27mA (max)</td>
</tr>
<tr data-start="2300" data-end="2334">
<td data-start="2300" data-end="2321" data-col-size="sm"><strong data-start="2302" data-end="2320">Sounder Output</strong></td>
<td data-start="2321" data-end="2334" data-col-size="md">200mA max</td>
</tr>
<tr data-start="2335" data-end="2384">
<td data-start="2335" data-end="2370" data-col-size="sm"><strong data-start="2337" data-end="2369">Routing Outputs (Fire/Fault)</strong></td>
<td data-start="2370" data-end="2384" data-col-size="md">200mA each</td>
</tr>
<tr data-start="2385" data-end="2430">
<td data-start="2385" data-end="2414" data-col-size="sm"><strong data-start="2387" data-end="2413">Communication Protocol</strong></td>
<td data-start="2414" data-end="2430" data-col-size="md">2-wire RS485</td>
</tr>
<tr data-start="2431" data-end="2463">
<td data-start="2431" data-end="2450" data-col-size="sm"><strong data-start="2433" data-end="2449">EOL Resistor</strong></td>
<td data-start="2450" data-end="2463" data-col-size="md">6.8KΩ, 1W</td>
</tr>
<tr data-start="2464" data-end="2562">
<td data-start="2464" data-end="2489" data-col-size="sm"><strong data-start="2466" data-end="2488">Recommended Wiring</strong></td>
<td data-start="2489" data-end="2562" data-col-size="md">220V AC: 16AWG / Panel-Interface: 20AWG / Main Board-Interface: 28AWG</td>
</tr>
<tr data-start="2563" data-end="2642">
<td data-start="2563" data-end="2582" data-col-size="sm"><strong data-start="2565" data-end="2581">Fuse Ratings</strong></td>
<td data-start="2582" data-end="2642" data-col-size="md">Power: 3A / General: 0.2A ×5 / Main: 2A / EM Valve: 1.5A</td>
</tr>
<tr data-start="2643" data-end="2688">
<td data-start="2643" data-end="2671" data-col-size="sm"><strong data-start="2645" data-end="2670">Operating Temperature</strong></td>
<td data-start="2671" data-end="2688" data-col-size="md">–5°C to +40°C</td>
</tr>
<tr data-start="2689" data-end="2732">
<td data-start="2689" data-end="2704" data-col-size="sm"><strong data-start="2691" data-end="2703">Humidity</strong></td>
<td data-start="2704" data-end="2732" data-col-size="md">5–95% RH, non-condensing</td>
</tr>
<tr data-start="2733" data-end="2784">
<td data-start="2733" data-end="2749" data-col-size="sm"><strong data-start="2735" data-end="2748">Enclosure</strong></td>
<td data-start="2749" data-end="2784" data-col-size="md">Metal cabinet with glass window</td>
</tr>
<tr data-start="2785" data-end="2840">
<td data-start="2785" data-end="2813" data-col-size="sm"><strong data-start="2787" data-end="2812">Terminal Block Rating</strong></td>
<td data-start="2813" data-end="2840" data-col-size="md">12–18 AWG (0.75–2.5mm²)</td>
</tr>
<tr data-start="2841" data-end="2907">
<td data-start="2841" data-end="2858" data-col-size="sm"><strong data-start="2843" data-end="2857">Dimensions</strong></td>
<td data-start="2858" data-end="2907" data-col-size="md">[Not provided – typically depends on cabinet]</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p data-start="2936" data-end="3146"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Commercial &amp; Industrial Buildings<br data-start="2972" data-end="2975" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Gas Extinguishing Systems<br data-start="3003" data-end="3006" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Educational Institutions<br data-start="3033" data-end="3036" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Facilities<br data-start="3072" data-end="3075" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4e6.png" alt="📦" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Warehouses &amp; Storage Areas<br data-start="3104" data-end="3107" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Malls &amp; Public Facilities</p>
</div>
</div>
</div>
<div class="main">
<hr data-start="2909" data-end="2912" />
<p><strong data-start="2448" data-end="2481"><img decoding="async" class="emoji" role="img" draggable="false" src="https://s.w.org/images/core/emoji/16.0.1/svg/1f6d2.svg" alt="&#x1f6d2;" /> Available Now at City Fire</strong><br data-start="2481" data-end="2484" />✓ Trusted Quality<br data-start="2501" data-end="2504" />✓ Certified Performance<br data-start="2527" data-end="2530" />✓ Fast Nationwide Delivery</p>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/extinguishing-panel-asenware/">Extinguishing Panel Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fire Resistant Cable Asenware</title>
		<link>https://www.cityfireservice.com/shop/fire-resistant-cable-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-resistant-cable-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 10:37:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4160</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">
<div class="name">
<p class="name"><strong>Fire Resistant Cable 2×1.5</strong></p>
<div class="desc">AW-FPC2×1.5 Fire Resistant Cable is used where critical circuits need to function to keep safety equipment running even when exposed to extreme heat or fire...</div>
</div>
<div><span style="color: #ff6600;"><strong>Price 280/- Per Meter</strong></span></div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-resistant-cable-asenware/">Fire Resistant Cable Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<div class="art_bor">
<div class="main">
<div class="art_title">
<h4 data-start="131" data-end="167"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> UL Listed Fire Resistant Cable</h4>
<p data-start="168" data-end="206">Model: AW-FPLR2X1.5 (16 AWG)</p>
<hr data-start="208" data-end="211" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="240" data-end="610">The AW-FPC 2-core 1.5mm Fire Resistant Cable is designed for critical safety circuits that must remain operational during extreme heat and fire conditions. With multi-stranded tinned copper conductors, aluminum foil shielding, and durable fire-resistant PVC covering, this cable ensures reliable performance and compliance in life-safety installations.</p>
<p data-start="612" data-end="761">It is ideal for fire alarm systems, emergency lighting, smoke control, and firefighting equipment wiring where uninterrupted function is vital.</p>
<hr data-start="763" data-end="766" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="789" data-end="1331">
<li data-start="789" data-end="864">
<p data-start="791" data-end="864"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Resistant – Maintains circuit integrity during fire exposure</p>
</li>
<li data-start="865" data-end="957">
<p data-start="867" data-end="957"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> High-Quality Conductor – Multi-stranded tinned copper for flexibility &amp; durability</p>
</li>
<li data-start="958" data-end="1023">
<p data-start="960" data-end="1023"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Reliable Insulation – AV thickness 0.38mm (min. 0.33mm)</p>
</li>
<li data-start="1024" data-end="1102">
<p data-start="1026" data-end="1102"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shielded Protection – Aluminum foil winding for reduced interference</p>
</li>
<li data-start="1103" data-end="1174">
<p data-start="1105" data-end="1174"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Color-Coded Core Wires – Easy identification and installation</p>
</li>
<li data-start="1175" data-end="1255">
<p data-start="1177" data-end="1255"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable Outer Sheath – Red UL105° PVC, fire-retardant and long-lasting</p>
</li>
<li data-start="1256" data-end="1331">
<p data-start="1258" data-end="1331"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Complies with Safety Standards – Engineered for critical circuits</p>
</li>
</ul>
<hr data-start="1333" data-end="1336" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1373" data-end="1996">
<thead data-start="1373" data-end="1402">
<tr data-start="1373" data-end="1402">
<th data-start="1373" data-end="1385" data-col-size="sm">Parameter</th>
<th data-start="1385" data-end="1402" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1433" data-end="1996">
<tr data-start="1433" data-end="1470">
<td data-start="1433" data-end="1445" data-col-size="sm"><strong data-start="1435" data-end="1444">Model</strong></td>
<td data-start="1445" data-end="1470" data-col-size="md">AW-FPLR2X1.5 (16 AWG)</td>
</tr>
<tr data-start="1471" data-end="1511">
<td data-start="1471" data-end="1482" data-col-size="sm"><strong data-start="1473" data-end="1481">Type</strong></td>
<td data-start="1482" data-end="1511" data-col-size="md">Multi-stranded fire cable</td>
</tr>
<tr data-start="1512" data-end="1569">
<td data-start="1512" data-end="1528" data-col-size="sm"><strong data-start="1514" data-end="1527">Conductor</strong></td>
<td data-start="1528" data-end="1569" data-col-size="md">Tinned copper stranded, Ø max. 0.50mm</td>
</tr>
<tr data-start="1570" data-end="1621">
<td data-start="1570" data-end="1608" data-col-size="sm"><strong data-start="1572" data-end="1607">Max Conductor Resistance (20°C)</strong></td>
<td data-start="1608" data-end="1621" data-col-size="md">13.7 Ω/km</td>
</tr>
<tr data-start="1622" data-end="1676">
<td data-start="1622" data-end="1649" data-col-size="sm"><strong data-start="1624" data-end="1648">Insulation Thickness</strong></td>
<td data-start="1649" data-end="1676" data-col-size="md">AV: 0.38mm, Min: 0.33mm</td>
</tr>
<tr data-start="1677" data-end="1716">
<td data-start="1677" data-end="1693" data-col-size="sm"><strong data-start="1679" data-end="1692">Core Wire</strong></td>
<td data-start="1693" data-end="1716" data-col-size="md">Color-coded with ID</td>
</tr>
<tr data-start="1717" data-end="1752">
<td data-start="1717" data-end="1733" data-col-size="sm"><strong data-start="1719" data-end="1732">Stranding</strong></td>
<td data-start="1733" data-end="1752" data-col-size="md">2-core stranded</td>
</tr>
<tr data-start="1753" data-end="1828">
<td data-start="1753" data-end="1771" data-col-size="sm"><strong data-start="1755" data-end="1770">Ground Wire</strong></td>
<td data-start="1771" data-end="1828" data-col-size="md">Tinned copper stranded, Ø max. 0.26mm (single strand)</td>
</tr>
<tr data-start="1829" data-end="1896">
<td data-start="1829" data-end="1853" data-col-size="sm"><strong data-start="1831" data-end="1852">Shielding/Winding</strong></td>
<td data-start="1853" data-end="1896" data-col-size="md">Aluminum foil (conductive layer inward)</td>
</tr>
<tr data-start="1897" data-end="1946">
<td data-start="1897" data-end="1918" data-col-size="sm"><strong data-start="1899" data-end="1917">Outer Covering</strong></td>
<td data-start="1918" data-end="1946" data-col-size="md">Red PVC (UL105° PVC-55P)</td>
</tr>
<tr data-start="1947" data-end="1996">
<td data-start="1947" data-end="1965" data-col-size="sm"><strong data-start="1949" data-end="1964">Application</strong></td>
<td data-start="1965" data-end="1996" data-col-size="md">Fire alarm &amp; safety systems</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p data-start="2025" data-end="2192"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6a8.png" alt="🚨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Alarm Systems<br data-start="2046" data-end="2049" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4a1.png" alt="💡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Emergency Lighting Circuits<br data-start="2079" data-end="2082" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4a8.png" alt="💨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Smoke &amp; Ventilation Systems<br data-start="2112" data-end="2115" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Suppression Equipment Wiring<br data-start="2151" data-end="2154" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Commercial &amp; Industrial Buildings</p>
<div class="main">
<hr data-start="2909" data-end="2912" />
<p><strong data-start="2448" data-end="2481"><img decoding="async" class="emoji" role="img" draggable="false" src="https://s.w.org/images/core/emoji/16.0.1/svg/1f6d2.svg" alt="&#x1f6d2;" /> Available Now at City Fire</strong><br data-start="2481" data-end="2484" />✓ Trusted Quality<br data-start="2501" data-end="2504" />✓ Certified Performance<br data-start="2527" data-end="2530" />✓ Fast Nationwide Delivery</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-resistant-cable-asenware/">Fire Resistant Cable Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Reflective Beam Detector Asenware</title>
		<link>https://www.cityfireservice.com/shop/reflective-beam-detector-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=reflective-beam-detector-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 10:20:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4152</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">
<p class="sr-proMainInfo-baseInfoH1 J-baseInfo-name">The AW-D130A (Addressable) and AW-D130C (Conventional, LPCB Approved) reflective optical beam smoke detectors are designed for reliable fire detection in large open areas such as warehouses, factories, shopping malls, and atriums.</p>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/reflective-beam-detector-asenware/">Reflective Beam Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<div class="prodetacr_name">
<h3 data-start="0" data-end="51">Two-Wire Addressable Fire Alarm Control System</h3>
<h4 data-start="52" data-end="109">Reflective Optical Beam Smoke Detector – <strong data-start="97" data-end="109">AW-D130A</strong></h4>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div>
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<div class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-e-xl">The <strong data-start="157" data-end="208">AW-D130A Reflective Optical Beam Smoke Detector</strong> is designed for use in two-wire addressable fire alarm systems. It utilizes a high-precision symmetrical infrared laser to ensure excellent long-distance focusing, strong signal consistency, and long-term operational stability.</div>
</div>
</div>
</div>
<p data-start="438" data-end="675">Its refined and practical design includes multiple connection terminals, allowing flexible and convenient installation. The detector is compatible with AW-FP100/128/200/2166 series addressable fire alarm control panels (model dependent).</p>
<h4 data-start="677" data-end="697">Product Overview</h4>
<p data-start="698" data-end="998">The detector operates by transmitting and receiving an infrared beam reflected from a prism reflector. When smoke obscures the beam beyond a preset threshold, the system generates an alarm signal. This makes it especially suitable for large open areas where point-type detectors may not be practical.</p>
<h4 data-start="1000" data-end="1020">Product Features</h4>
<ul data-start="1021" data-end="1263">
<li data-start="1021" data-end="1061">
<p data-start="1023" data-end="1061">Supports built-in isolation function</p>
</li>
<li data-start="1062" data-end="1130">
<p data-start="1064" data-end="1130">Infrared remote control operation for easy setup and maintenance</p>
</li>
<li data-start="1131" data-end="1186">
<p data-start="1133" data-end="1186">Ideal for large warehouses and open-area protection</p>
</li>
<li data-start="1187" data-end="1221">
<p data-start="1189" data-end="1221">Complies with EN54-12 standard</p>
</li>
<li data-start="1222" data-end="1263">
<p data-start="1224" data-end="1263">Optical detection range: <strong data-start="1249" data-end="1263">5m to 160m</strong></p>
</li>
</ul>
<h4 data-start="1265" data-end="1289">Technical Parameters</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1291" data-end="1668">
<thead data-start="1291" data-end="1320">
<tr data-start="1291" data-end="1320">
<th class="" data-start="1291" data-end="1303" data-col-size="sm">Parameter</th>
<th class="" data-start="1303" data-end="1320" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1351" data-end="1668">
<tr data-start="1351" data-end="1391">
<td data-start="1351" data-end="1366" data-col-size="sm">Main Voltage</td>
<td data-col-size="md" data-start="1366" data-end="1391">LOOP 24V or DC 12–24V</td>
</tr>
<tr data-start="1392" data-end="1459">
<td data-start="1392" data-end="1410" data-col-size="sm">Working Current</td>
<td data-col-size="md" data-start="1410" data-end="1459">Static ≤10mA @ DC 24V<br />
Alarm ≤15mA @ DC 24V</td>
</tr>
<tr data-start="1460" data-end="1496">
<td data-start="1460" data-end="1482" data-col-size="sm">Laser Concentricity</td>
<td data-col-size="md" data-start="1482" data-end="1496">≤1° @ 160m</td>
</tr>
<tr data-start="1497" data-end="1530">
<td data-start="1497" data-end="1504" data-col-size="sm">Size</td>
<td data-col-size="md" data-start="1504" data-end="1530">184.3 × 143.3 × 120 mm</td>
</tr>
<tr data-start="1531" data-end="1570">
<td data-start="1531" data-end="1552" data-col-size="sm">Detection Distance</td>
<td data-col-size="md" data-start="1552" data-end="1570">5 – 160 meters</td>
</tr>
<tr data-start="1571" data-end="1628">
<td data-start="1571" data-end="1595" data-col-size="sm">Operating Temperature</td>
<td data-col-size="md" data-start="1595" data-end="1628">-10°C to 50°C (14°F to 122°F)</td>
</tr>
<tr data-start="1629" data-end="1668">
<td data-start="1629" data-end="1640" data-col-size="sm">Humidity</td>
<td data-col-size="md" data-start="1640" data-end="1668">≤95% RH (non-condensing)</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl"><img decoding="async" class="bg-token-main-surface-tertiary m-0 h-full w-full object-cover" src="https://ueeshop.ly200-cdn.com/u_file/UPAU/UPAU285/2205/photo/a4f8512242.jpg" alt="https://ueeshop.ly200-cdn.com/u_file/UPAU/UPAU285/2205/photo/a4f8512242.jpg" /><img fetchpriority="high" decoding="async" class="bg-token-main-surface-tertiary m-0 h-full w-full object-cover" src="https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-beam200-intelligent-reflected-beam-smoke-detector-primaryimage" alt="https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-beam200-intelligent-reflected-beam-smoke-detector-primaryimage" width="300" height="370" /></div>
<hr data-start="1670" data-end="1673" />
<h3 data-start="1675" data-end="1734">Conventional Fire Alarm Control System (LPCB Approved)</h3>
<h4 data-start="1735" data-end="1792">Reflective Optical Beam Smoke Detector – <strong data-start="1780" data-end="1792">AW-D130C</strong></h4>
<p data-start="1836" data-end="2119">The <strong data-start="1840" data-end="1891">AW-D130C Reflective Optical Beam Smoke Detector</strong> is designed for conventional fire alarm control systems and is LPCB approved. It features the same high-precision symmetrical infrared laser technology, ensuring stable performance, long-range detection, and reliable operation.</p>
<p data-start="2121" data-end="2321">Its practical housing design provides flexible terminal connections for easy system integration. It can be connected to compatible conventional fire alarm panels in the AW-FP series (model dependent).</p>
<h4 data-start="2323" data-end="2343">Product Overview</h4>
<p data-start="2344" data-end="2554">The AW-D130C is ideal for wide and open indoor spaces where installing multiple point detectors would be inefficient. It ensures early smoke detection across long distances with minimal installation complexity.</p>
<h4 data-start="2556" data-end="2576">Product Features</h4>
<ul data-start="2577" data-end="2722">
<li data-start="2577" data-end="2608">
<p data-start="2579" data-end="2608">Supports isolation function</p>
</li>
<li data-start="2609" data-end="2646">
<p data-start="2611" data-end="2646">Infrared remote control operation</p>
</li>
<li data-start="2647" data-end="2695">
<p data-start="2649" data-end="2695">Suitable for warehouses and large open areas</p>
</li>
<li data-start="2696" data-end="2722">
<p data-start="2698" data-end="2722">Meets EN54-12 standard</p>
</li>
</ul>
<h4 data-start="2724" data-end="2748">Technical Parameters</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2750" data-end="3029">
<thead data-start="2750" data-end="2779">
<tr data-start="2750" data-end="2779">
<th class="" data-start="2750" data-end="2762" data-col-size="sm">Parameter</th>
<th class="" data-start="2762" data-end="2779" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="2810" data-end="3029">
<tr data-start="2810" data-end="2850">
<td data-start="2810" data-end="2825" data-col-size="sm">Main Voltage</td>
<td data-col-size="md" data-start="2825" data-end="2850">LOOP 24V or DC 12–24V</td>
</tr>
<tr data-start="2851" data-end="2918">
<td data-start="2851" data-end="2869" data-col-size="sm">Working Current</td>
<td data-col-size="md" data-start="2869" data-end="2918">Static ≤10mA @ DC 24V<br />
Alarm ≤15mA @ DC 24V</td>
</tr>
<tr data-start="2919" data-end="2955">
<td data-start="2919" data-end="2941" data-col-size="sm">Laser Concentricity</td>
<td data-col-size="md" data-start="2941" data-end="2955">≤1° @ 160m</td>
</tr>
<tr data-start="2956" data-end="2989">
<td data-start="2956" data-end="2963" data-col-size="sm">Size</td>
<td data-col-size="md" data-start="2963" data-end="2989">184.3 × 143.3 × 120 mm</td>
</tr>
<tr data-start="2990" data-end="3029">
<td data-start="2990" data-end="3011" data-col-size="sm">Detection Distance</td>
<td data-col-size="md" data-start="3011" data-end="3029">5 – 160 meters</td>
</tr>
</tbody>
</table>
</div>
</div>
<h4 data-start="3036" data-end="3084">Key Difference Between AW-D130A and AW-D130C</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="3086" data-end="3319">
<thead data-start="3086" data-end="3119">
<tr data-start="3086" data-end="3119">
<th class="" data-start="3086" data-end="3096" data-col-size="sm">Feature</th>
<th class="" data-start="3096" data-end="3107" data-col-size="sm">AW-D130A</th>
<th class="" data-start="3107" data-end="3119" data-col-size="sm">AW-D130C</th>
</tr>
</thead>
<tbody data-start="3159" data-end="3319">
<tr data-start="3159" data-end="3203">
<td data-start="3159" data-end="3173" data-col-size="sm">System Type</td>
<td data-col-size="sm" data-start="3173" data-end="3187">Addressable</td>
<td data-col-size="sm" data-start="3187" data-end="3203">Conventional</td>
</tr>
<tr data-start="3204" data-end="3246">
<td data-start="3204" data-end="3220" data-col-size="sm">LPCB Approved</td>
<td data-col-size="sm" data-start="3220" data-end="3239">Depends on model</td>
<td data-col-size="sm" data-start="3239" data-end="3246">Yes</td>
</tr>
<tr data-start="3247" data-end="3319">
<td data-start="3247" data-end="3263" data-col-size="sm">Communication</td>
<td data-col-size="sm" data-start="3263" data-end="3291">Two-wire addressable loop</td>
<td data-col-size="sm" data-start="3291" data-end="3319">Conventional zone wiring</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/reflective-beam-detector-asenware/">Reflective Beam Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Addressable Fire Alarm Control Panel Asenware</title>
		<link>https://www.cityfireservice.com/shop/addressable-fire-alarm-control-panel-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=addressable-fire-alarm-control-panel-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 09:53:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4148</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">Addressable Fire Alarm Control Panel 02 Loop AW-FP200</div>
<div class="brief">are intelligent panel which are carefully designed to make it suitable for most of applications. It can be configured with other panels or control systems.</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/addressable-fire-alarm-control-panel-asenware/">Addressable Fire Alarm Control Panel Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<h4 data-start="178" data-end="236"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Asenware TUV Approved Addressable Fire Alarm System</h4>
<h6 data-start="237" data-end="286">Models: <strong data-start="249" data-end="284">FP202 (2-Loop) &amp; FP204 (4-Loop)</strong></h6>
<hr data-start="313" data-end="316" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="345" data-end="515">The Asenware AW-FP200 series (FP202 and FP204) is a TÜV-approved addressable fire alarm system designed for reliable fire detection and intelligent control.</p>
<p data-start="517" data-end="703">Featuring a 7-inch color LCD touchscreen with button operation, the system offers an intuitive interface and multi-language support, making it suitable for global applications.</p>
<p data-start="705" data-end="923">With support for up to 8 loops (250 devices per loop) and wireless integration, the AW-FP200 series is ideal for residential complexes, commercial buildings, industrial facilities, and high-rise projects.</p>
</div>
</div>
</div>
<div class="main">
<div class="p_del">
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="951" data-end="1848">
<li data-start="951" data-end="1029">
<p data-start="953" data-end="1029"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 7-inch Touchscreen LCD – User-friendly operation and clear interface</p>
</li>
<li data-start="1030" data-end="1085">
<p data-start="1032" data-end="1085"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Two-Wire System – For all addressable devices</p>
</li>
<li data-start="1086" data-end="1196">
<p data-start="1088" data-end="1196"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Flexible Device Connectivity – 250 wired devices per loop, plus 10 wireless groups (20 devices each)</p>
</li>
<li data-start="1197" data-end="1255">
<p data-start="1199" data-end="1255"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Expandable – Up to 8 loop cards can be installed</p>
</li>
<li data-start="1256" data-end="1341">
<p data-start="1258" data-end="1341"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Event Storage – Saves up to 999 records (retains history during power loss)</p>
</li>
<li data-start="1342" data-end="1413">
<p data-start="1344" data-end="1413"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Multi-Level Access Control – Enhances security and management</p>
</li>
<li data-start="1414" data-end="1484">
<p data-start="1416" data-end="1484"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Automatic Device Search – Simplifies commissioning and setup</p>
</li>
<li data-start="1485" data-end="1557">
<p data-start="1487" data-end="1557"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Remote Monitoring – Supports up to 8 hosts with remote control</p>
</li>
<li data-start="1558" data-end="1656">
<p data-start="1560" data-end="1656"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Mobile Alerts – Up to 10 phone numbers can receive alarm notifications (with GSM module)</p>
</li>
<li data-start="1657" data-end="1724">
<p data-start="1659" data-end="1724"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> USB Interface – Check status and history from PC software</p>
</li>
<li data-start="1725" data-end="1793">
<p data-start="1727" data-end="1793"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Rechargeable Battery Backup – Ensures continuous operation</p>
</li>
<li data-start="1794" data-end="1848">
<p data-start="1796" data-end="1848"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> LED Indicators – Quick status identification</p>
</li>
</ul>
</div>
</div>
<div>
<div class="art_bor">
<div class="main">
<div class="art_title">
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1890" data-end="2785">
<thead data-start="1890" data-end="1919">
<tr data-start="1890" data-end="1919">
<th data-start="1890" data-end="1902" data-col-size="sm">Parameter</th>
<th data-start="1902" data-end="1919" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1950" data-end="2785">
<tr data-start="1950" data-end="1997">
<td data-start="1950" data-end="1963" data-col-size="sm"><strong data-start="1952" data-end="1962">Models</strong></td>
<td data-start="1963" data-end="1997" data-col-size="md">FP202 (2-Loop), FP204 (4-Loop)</td>
</tr>
<tr data-start="1998" data-end="2023">
<td data-start="1998" data-end="2011" data-col-size="sm"><strong data-start="2000" data-end="2010">Series</strong></td>
<td data-start="2011" data-end="2023" data-col-size="md">AW-FP200</td>
</tr>
<tr data-start="2024" data-end="2072">
<td data-start="2024" data-end="2050" data-col-size="sm"><strong data-start="2026" data-end="2049">Rated Input Voltage</strong></td>
<td data-start="2050" data-end="2072" data-col-size="md">85–260VAC, 50/60Hz</td>
</tr>
<tr data-start="2073" data-end="2134">
<td data-start="2073" data-end="2095" data-col-size="sm"><strong data-start="2075" data-end="2094">Standby Battery</strong></td>
<td data-start="2095" data-end="2134" data-col-size="md">2 × 12V / 7Ah lead-acid (in series)</td>
</tr>
<tr data-start="2135" data-end="2205">
<td data-start="2135" data-end="2161" data-col-size="sm"><strong data-start="2137" data-end="2160">Working Environment</strong></td>
<td data-start="2161" data-end="2205" data-col-size="md">–10°C to +45°C, ≤95% RH (non-condensing)</td>
</tr>
<tr data-start="2206" data-end="2314">
<td data-start="2206" data-end="2218" data-col-size="sm"><strong data-start="2208" data-end="2217">Fuses</strong></td>
<td data-start="2218" data-end="2314" data-col-size="md">AC Input: 3.15A / 250V (glass, slow blow)<br />
Battery Output: 10A / 250V (glass, slow blow)</td>
</tr>
<tr data-start="2315" data-end="2375">
<td data-start="2315" data-end="2344" data-col-size="sm"><strong data-start="2317" data-end="2343">Auxiliary Power Supply</strong></td>
<td data-start="2344" data-end="2375" data-col-size="md">Resettable 24VDC, 200mA max</td>
</tr>
<tr data-start="2376" data-end="2420">
<td data-start="2376" data-end="2400" data-col-size="sm"><strong data-start="2378" data-end="2399">Fire Alarm Output</strong></td>
<td data-start="2400" data-end="2420" data-col-size="md">24VDC, 200mA max</td>
</tr>
<tr data-start="2421" data-end="2481">
<td data-start="2421" data-end="2440" data-col-size="sm"><strong data-start="2423" data-end="2439">Fault Output</strong></td>
<td data-start="2440" data-end="2481" data-col-size="md">24VDC, 200mA (normal), –12VDC (fault)</td>
</tr>
<tr data-start="2482" data-end="2557">
<td data-start="2482" data-end="2513" data-col-size="sm"><strong data-start="2484" data-end="2512">Supervisory (S.C) Output</strong></td>
<td data-start="2513" data-end="2557" data-col-size="md">–12VDC (normal), –24VDC / 200mA (active)</td>
</tr>
<tr data-start="2558" data-end="2607">
<td data-start="2558" data-end="2590" data-col-size="sm"><strong data-start="2560" data-end="2589">Max Load Current per Loop</strong></td>
<td data-start="2590" data-end="2607" data-col-size="md">24VDC, 1A max</td>
</tr>
<tr data-start="2608" data-end="2663">
<td data-start="2608" data-end="2636" data-col-size="sm"><strong data-start="2610" data-end="2635">Terminal Block Rating</strong></td>
<td data-start="2636" data-end="2663" data-col-size="md">12–18 AWG (0.75–2.5mm²)</td>
</tr>
<tr data-start="2664" data-end="2738">
<td data-start="2664" data-end="2692" data-col-size="sm"><strong data-start="2666" data-end="2691">Transmission Distance</strong></td>
<td data-start="2692" data-end="2738" data-col-size="md">≤1000m (twisted pair, screened/unscreened)</td>
</tr>
<tr data-start="2739" data-end="2785">
<td data-start="2739" data-end="2753" data-col-size="sm"><strong data-start="2741" data-end="2752">Display</strong></td>
<td data-start="2753" data-end="2785" data-col-size="md">7-inch color LCD touchscreen</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<h4 data-start="1931" data-end="1964"><img decoding="async" class="" src="https://www.cityfireservice.com/wp-content/uploads/2024/09/WhatsApp-Image-2026-02-25-at-2.59.26-PM.jpeg" width="1412" height="794" /></h4>
<p><strong><span style="font-size: 30px;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> </span></strong><span style="font-size: 30px;">Applications</span></p>
<div class="art_bor">
<div class="main">
<div class="art_title">
<p data-start="2814" data-end="2987"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Commercial &amp; Office Buildings<br data-start="2846" data-end="2849" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Malls<br data-start="2866" data-end="2869" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Complexes<br data-start="2892" data-end="2895" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Towers<br data-start="2916" data-end="2919" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Educational Institutions<br data-start="2946" data-end="2949" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Facilities</p>
<div class="main">
<hr data-start="2909" data-end="2912" />
<p><strong data-start="2448" data-end="2481"><img decoding="async" class="emoji" role="img" draggable="false" src="https://s.w.org/images/core/emoji/16.0.1/svg/1f6d2.svg" alt="&#x1f6d2;" /> Available Now at City Fire</strong><br data-start="2481" data-end="2484" />✓ Trusted Quality<br data-start="2501" data-end="2504" />✓ Certified Performance<br data-start="2527" data-end="2530" />✓ Fast Nationwide Delivery</p>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/addressable-fire-alarm-control-panel-asenware/">Addressable Fire Alarm Control Panel Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fire Alarm Strobe Sounder Asenware</title>
		<link>https://www.cityfireservice.com/shop/fire-alarm-strobe-sounder-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-alarm-strobe-sounder-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 09:49:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4146</guid>

					<description><![CDATA[<div class="name">Designed for compatibility with addressable and conventional fire alarm control panels, these devices ensure clear evacuation signaling through high sound output &#38; bright flashing strobes. Ideal for commercial, residential &#38; industrial fire safety applications.</div>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-alarm-strobe-sounder-asenware/">Fire Alarm Strobe Sounder Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<article class="text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto scroll-mt-(--header-height)" dir="auto" tabindex="-1" data-turn-id="761783af-5e9f-4240-8bc7-9602f64384c3" data-testid="conversation-turn-7" data-scroll-anchor="false" data-turn="user"></article>
<article class="text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]" dir="auto" tabindex="-1" data-turn-id="request-WEB:0994350d-7913-405b-bb4c-2b5fb8f86b78-3" data-testid="conversation-turn-8" data-scroll-anchor="true" data-turn="assistant">
<div class="text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm/main:[--thread-content-margin:--spacing(6)] @w-lg/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)">
<div class="[--thread-content-max-width:40rem] @w-lg/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn" tabindex="-1">
<div class="flex max-w-full flex-col grow">
<div class="min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-1" dir="auto" data-message-author-role="assistant" data-message-id="a444a8f6-9fd9-4578-9b66-a7184cb1017c" data-message-model-slug="gpt-5-2">
<div class="flex w-full flex-col gap-1 empty:hidden first:pt-[1px]">
<div class="markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling">
<h3 data-start="0" data-end="49"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f514.png" alt="🔔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Alarm Sounder &amp; Horn Strobe Solutions</h3>
<h4 data-start="56" data-end="97"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f514.png" alt="🔔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Addressable Horn Strobe – AW-D106</h4>
<p data-start="98" data-end="170"><em data-start="98" data-end="170">(Compatible with AW-FP100 Series Addressable Fire Alarm Control Panel)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div>
<h4 class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44"><span style="color: #222222; font-size: 30px; font-weight: bold;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</span></h4>
</div>
</div>
<p data-start="241" data-end="380">The <strong data-start="245" data-end="256">AW-D106</strong> is an intelligent addressable horn strobe designed for use with the AW-FP100 Series addressable fire alarm control panel.</p>
<p data-start="382" data-end="624">Each unit is assigned a unique ID address, allowing precise monitoring of device location and status directly from the control panel. It delivers powerful audible and visual alerts, ensuring safe and efficient evacuation during emergencies.</p>
<p data-start="626" data-end="689">Ideal for commercial, residential, and industrial applications.</p>
<h5 data-start="691" data-end="711"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</h5>
<ul data-start="712" data-end="905">
<li data-start="712" data-end="750">
<p data-start="714" data-end="750"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Addressable-Analog Communication</p>
</li>
<li data-start="751" data-end="783">
<p data-start="753" data-end="783"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low Standby Current (≤3mA)</p>
</li>
<li data-start="784" data-end="815">
<p data-start="786" data-end="815"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> High Sound Output ≥100 dB</p>
</li>
<li data-start="816" data-end="866">
<p data-start="818" data-end="866"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Bright Strobe Flash (≤1 second flash period)</p>
</li>
<li data-start="867" data-end="905">
<p data-start="869" data-end="905"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Supplied with Mounting Enclosure</p>
</li>
</ul>
<h5 data-start="907" data-end="940"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h5>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="942" data-end="1172">
<thead data-start="942" data-end="971">
<tr data-start="942" data-end="971">
<th class="" data-start="942" data-end="954" data-col-size="sm">Parameter</th>
<th class="" data-start="954" data-end="971" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1002" data-end="1172">
<tr data-start="1002" data-end="1035">
<td data-start="1002" data-end="1022" data-col-size="sm">Operating Voltage</td>
<td data-col-size="sm" data-start="1022" data-end="1035">18–28V DC</td>
</tr>
<tr data-start="1036" data-end="1066">
<td data-start="1036" data-end="1054" data-col-size="sm">Working Current</td>
<td data-col-size="sm" data-start="1054" data-end="1066">10–60 mA</td>
</tr>
<tr data-start="1067" data-end="1101">
<td data-start="1067" data-end="1090" data-col-size="sm">Sound Pressure Level</td>
<td data-col-size="sm" data-start="1090" data-end="1101">≥100 dB</td>
</tr>
<tr data-start="1102" data-end="1129">
<td data-start="1102" data-end="1117" data-col-size="sm">Flash Period</td>
<td data-col-size="sm" data-start="1117" data-end="1129">≤1.0 sec</td>
</tr>
<tr data-start="1130" data-end="1172">
<td data-start="1130" data-end="1154" data-col-size="sm">Operating Temperature</td>
<td data-col-size="sm" data-start="1154" data-end="1172">–10°C to +50°C</td>
</tr>
</tbody>
</table>
</div>
</div>
<h4 data-start="1179" data-end="1229"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50a.png" alt="🔊" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Conventional Sounder Strobe – AW-CSS2166-2</h4>
<p data-start="1230" data-end="1305"><em data-start="1230" data-end="1305">(Compatible with AW-CFP2166 Series Conventional Fire Alarm Control Panel)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<p class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl"><span style="color: #222222; font-size: 30px; font-weight: bold;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50e.png" alt="🔎" class="wp-smiley" style="height: 1em; max-height: 1em;" /> </span><span style="color: #222222; font-size: 30px;">Product Overview </span>The AW-CSS2166-2 is a conventional fire alarm sounder strobe providing combined audible and visual warning signals.</p>
</div>
</div>
<p data-start="1498" data-end="1690">With ≥85 dB alarm output and a 1 flash per second strobe, it ensures clear notification across protected areas. It integrates seamlessly with AW-CFP2166 conventional fire alarm control panels.</p>
<p data-start="1692" data-end="1712"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</p>
<ul data-start="1713" data-end="1874">
<li data-start="1713" data-end="1750">
<p data-start="1715" data-end="1750"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Combined Audible &amp; Visual Alarm</p>
</li>
<li data-start="1751" data-end="1773">
<p data-start="1753" data-end="1773"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Alarm SPL ≥85 dB</p>
</li>
<li data-start="1774" data-end="1797">
<p data-start="1776" data-end="1797"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Flash Rate: 1/sec</p>
</li>
<li data-start="1798" data-end="1832">
<p data-start="1800" data-end="1832"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low Power Consumption ≤60 mA</p>
</li>
<li data-start="1833" data-end="1874">
<p data-start="1835" data-end="1874"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Compact, Durable ABS Housing (IP30)</p>
</li>
</ul>
<h5 data-start="1876" data-end="1909"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h5>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1911" data-end="2174">
<thead data-start="1911" data-end="1940">
<tr data-start="1911" data-end="1940">
<th class="" data-start="1911" data-end="1923" data-col-size="sm">Parameter</th>
<th class="" data-start="1923" data-end="1940" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1971" data-end="2174">
<tr data-start="1971" data-end="2003">
<td data-start="1971" data-end="1991" data-col-size="sm">Operating Voltage</td>
<td data-col-size="sm" data-start="1991" data-end="2003">Zone 24V</td>
</tr>
<tr data-start="2004" data-end="2034">
<td data-start="2004" data-end="2024" data-col-size="sm">Operating Current</td>
<td data-col-size="sm" data-start="2024" data-end="2034">≤60 mA</td>
</tr>
<tr data-start="2035" data-end="2068">
<td data-start="2035" data-end="2058" data-col-size="sm">Sound Pressure Level</td>
<td data-col-size="sm" data-start="2058" data-end="2068">≥85 dB</td>
</tr>
<tr data-start="2069" data-end="2096">
<td data-start="2069" data-end="2087" data-col-size="sm">Flash Frequency</td>
<td data-col-size="sm" data-start="2087" data-end="2096">1/sec</td>
</tr>
<tr data-start="2097" data-end="2137">
<td data-start="2097" data-end="2121" data-col-size="sm">Operating Temperature</td>
<td data-col-size="sm" data-start="2121" data-end="2137">-5°C to 40°C</td>
</tr>
<tr data-start="2138" data-end="2174">
<td data-start="2138" data-end="2151" data-col-size="sm">Dimensions</td>
<td data-col-size="sm" data-start="2151" data-end="2174">154 × 115 × 50.5 mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<h5 data-start="2181" data-end="2209"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Typical Applications</h5>
<p data-start="2211" data-end="2405"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Office Buildings<br data-start="2230" data-end="2233" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e8.png" alt="🏨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hotels &amp; Apartments<br data-start="2255" data-end="2258" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Centers &amp; Malls<br data-start="2285" data-end="2288" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Facilities<br data-start="2312" data-end="2315" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Universities<br data-start="2340" data-end="2343" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Centers<br data-start="2376" data-end="2379" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Complexes</p>
<p data-start="2211" data-end="2405"><img decoding="async" class="" src="https://www.cityfireservice.com/wp-content/uploads/2021/01/2292d887cc.jpg" width="333" height="378" /></p>
</div>
</div>
</div>
</div>
</div>
</div>
</article>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-alarm-strobe-sounder-asenware/">Fire Alarm Strobe Sounder Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Manual Call Point Asenware</title>
		<link>https://www.cityfireservice.com/shop/manual-call-point-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=manual-call-point-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 09:44:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4143</guid>

					<description><![CDATA[<div class="name">
<div class="brief">This manual call point (MCP) is one ofaddressable alarm device, which coordinate work.with the fire extinguishing controlpanel.Pressingthis MCP to output the signal to the panel when have fire alarm, and activate the sounder or strobe lights.The red indic...</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/manual-call-point-asenware/">Manual Call Point Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 data-start="0" data-end="54"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6d1.png" alt="🛑" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Manual Call Points – Addressable &amp; Conventional</h3>
<h4 data-start="61" data-end="109"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6d1.png" alt="🛑" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Addressable Manual Call Point – AW-D135A</h4>
<p data-start="110" data-end="156"><em data-start="110" data-end="156">(For Intelligent Two-Bus Fire Alarm Systems)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div>
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<p class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)]"><span style="color: #222222; font-size: 30px; font-weight: bold;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</span></p>
</div>
</div>
</div>
<p data-start="227" data-end="486">The <strong data-start="231" data-end="243">AW-D135A</strong> is an addressable manual call point designed for intelligent fire alarm systems. When activated, it sends an alarm signal to the control panel, which displays the device’s unique coded address and status for precise location identification.</p>
<p data-start="488" data-end="687">The red LED blinks during normal monitoring and remains steadily lit in alarm condition. It supports electronic coding (address range 1–250), ensuring flexible configuration and reliable performance.</p>
<h4 data-start="689" data-end="709"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</h4>
<ul data-start="710" data-end="955">
<li data-start="710" data-end="733">
<p data-start="712" data-end="733"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> EN54-11 Compliant</p>
</li>
<li data-start="734" data-end="788">
<p data-start="736" data-end="788"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Reusable Lever Type (no glass breaking required)</p>
</li>
<li data-start="789" data-end="828">
<p data-start="791" data-end="828"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Electronic Address Coding (1–250)</p>
</li>
<li data-start="829" data-end="892">
<p data-start="831" data-end="892"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> LED Status Indicator (Blinking = Normal / Steady = Alarm)</p>
</li>
<li data-start="893" data-end="929">
<p data-start="895" data-end="929"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Semi-flush or Surface Mounting</p>
</li>
<li data-start="930" data-end="955">
<p data-start="932" data-end="955"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable ABS Housing</p>
</li>
</ul>
<h4 data-start="957" data-end="990"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="992" data-end="1307">
<thead data-start="992" data-end="1021">
<tr data-start="992" data-end="1021">
<th class="" data-start="992" data-end="1004" data-col-size="sm">Parameter</th>
<th class="" data-start="1004" data-end="1021" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1052" data-end="1307">
<tr data-start="1052" data-end="1084">
<td data-start="1052" data-end="1072" data-col-size="sm">Operating Voltage</td>
<td data-start="1072" data-end="1084" data-col-size="sm">Loop 24V</td>
</tr>
<tr data-start="1085" data-end="1140">
<td data-start="1085" data-end="1105" data-col-size="sm">Operating Current</td>
<td data-col-size="sm" data-start="1105" data-end="1140">Monitoring ≤2 mA / Alarm ≤15 mA</td>
</tr>
<tr data-start="1141" data-end="1168">
<td data-start="1141" data-end="1160" data-col-size="sm">Protection Class</td>
<td data-col-size="sm" data-start="1160" data-end="1168">IP30</td>
</tr>
<tr data-start="1169" data-end="1211">
<td data-start="1169" data-end="1193" data-col-size="sm">Operating Temperature</td>
<td data-start="1193" data-end="1211" data-col-size="sm">–10°C to +55°C</td>
</tr>
<tr data-start="1212" data-end="1251">
<td data-start="1212" data-end="1223" data-col-size="sm">Humidity</td>
<td data-start="1223" data-end="1251" data-col-size="sm">≤95% RH (non-condensing)</td>
</tr>
<tr data-start="1252" data-end="1288">
<td data-start="1252" data-end="1265" data-col-size="sm">Dimensions</td>
<td data-col-size="sm" data-start="1265" data-end="1288">99 × 91.5 × 66.3 mm</td>
</tr>
<tr data-start="1289" data-end="1307">
<td data-start="1289" data-end="1298" data-col-size="sm">Weight</td>
<td data-col-size="sm" data-start="1298" data-end="1307">~95 g</td>
</tr>
</tbody>
</table>
</div>
</div>
<h3 data-start="1314" data-end="1363"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6a8.png" alt="🚨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Conventional Manual Call Point – AW-D135C</h3>
<p data-start="1364" data-end="1412"><em data-start="1364" data-end="1412">(For Two-Wire Conventional Fire Alarm Systems)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<div class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl">
<h4><span style="color: #222222; font-size: 30px; font-weight: bold;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50e.png" alt="🔎" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</span></h4>
</div>
</div>
</div>
<p data-start="1482" data-end="1672">The <strong data-start="1486" data-end="1498">AW-D135C</strong> is a conventional manual call point designed for two-wire fire alarm systems. When pressed, it sends an alarm signal to the control panel, ensuring immediate notification.</p>
<p data-start="1674" data-end="1836">The red LED indicator blinks during normal monitoring and remains steadily lit during alarm. The unit includes a reset key for quick restoration after activation.</p>
<h4 data-start="1838" data-end="1858"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</h4>
<ul data-start="1859" data-end="2059">
<li data-start="1859" data-end="1896">
<p data-start="1861" data-end="1896"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Two-Wire Conventional Operation</p>
</li>
<li data-start="1897" data-end="1923">
<p data-start="1899" data-end="1923"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> LED Status Indicator</p>
</li>
<li data-start="1924" data-end="1956">
<p data-start="1926" data-end="1956"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Resettable Design with Key</p>
</li>
<li data-start="1957" data-end="1997">
<p data-start="1959" data-end="1997"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Semi-flush or Surface Installation</p>
</li>
<li data-start="1998" data-end="2028">
<p data-start="2000" data-end="2028"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable ABS Construction</p>
</li>
<li data-start="2029" data-end="2059">
<p data-start="2031" data-end="2059"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> EN54 Standard Compliance</p>
</li>
</ul>
<h4 data-start="2061" data-end="2094"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2096" data-end="2337">
<thead data-start="2096" data-end="2125">
<tr data-start="2096" data-end="2125">
<th class="" data-start="2096" data-end="2108" data-col-size="sm">Parameter</th>
<th class="" data-start="2108" data-end="2125" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="2156" data-end="2337">
<tr data-start="2156" data-end="2203">
<td data-start="2156" data-end="2176" data-col-size="sm">Operating Voltage</td>
<td data-start="2176" data-end="2203" data-col-size="sm">24V DC (via panel loop)</td>
</tr>
<tr data-start="2204" data-end="2255">
<td data-start="2204" data-end="2219" data-col-size="sm">Installation</td>
<td data-start="2219" data-end="2255" data-col-size="sm">Semi-recessed or Surface-mounted</td>
</tr>
<tr data-start="2256" data-end="2284">
<td data-start="2256" data-end="2271" data-col-size="sm">Reset Method</td>
<td data-col-size="sm" data-start="2271" data-end="2284">Reset key</td>
</tr>
<tr data-start="2285" data-end="2308">
<td data-start="2285" data-end="2296" data-col-size="sm">Material</td>
<td data-start="2296" data-end="2308" data-col-size="sm">ABS, Red</td>
</tr>
<tr data-start="2309" data-end="2337">
<td data-start="2309" data-end="2323" data-col-size="sm">Application</td>
<td data-start="2323" data-end="2337" data-col-size="sm">Indoor Use</td>
</tr>
</tbody>
</table>
</div>
</div>
<h4 data-start="2344" data-end="2364"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</h4>
<p data-start="2366" data-end="2559"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Commercial Buildings<br data-start="2389" data-end="2392" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Centers<br data-start="2411" data-end="2414" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Facilities<br data-start="2438" data-end="2441" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e8.png" alt="🏨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hotels &amp; Apartments<br data-start="2463" data-end="2466" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Universities<br data-start="2491" data-end="2494" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Facilities<br data-start="2530" data-end="2533" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Complexes</p>
<p>The post <a href="https://www.cityfireservice.com/shop/manual-call-point-asenware/">Manual Call Point Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Smoke Detector Asenware</title>
		<link>https://www.cityfireservice.com/shop/smoke-detector-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=smoke-detector-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 09:30:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4136</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">Designed for seamless integration with addressable and conventional control panels, these detectors ensure accurate monitoring, low power consumption, and dependable performance in residential, commercial, and industrial environments.</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/smoke-detector-asenware/">Smoke Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="relative basis-auto flex-col -mb-(--composer-overlap-px) [--composer-overlap-px:28px] grow flex">
<div class="flex flex-col text-sm">
<article class="text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]" dir="auto" tabindex="-1" data-turn-id="request-699dc47d-1b24-8321-8227-d58c74ed3076-0" data-testid="conversation-turn-16" data-scroll-anchor="true" data-turn="assistant">
<div class="text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm/main:[--thread-content-margin:--spacing(6)] @w-lg/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)">
<div class="[--thread-content-max-width:40rem] @w-lg/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn" tabindex="-1">
<div class="flex max-w-full flex-col grow">
<div class="min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-1" dir="auto" data-message-author-role="assistant" data-message-id="fdf7a8ab-a867-4a02-8859-57ec66629ca6" data-message-model-slug="gpt-5-2">
<div class="flex w-full flex-col gap-1 empty:hidden first:pt-[1px]">
<div class="markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling">
<h3 data-start="0" data-end="61">Smoke Detectors – Addressable &amp; Conventional Solutions</h3>
<h4 data-start="68" data-end="112"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Addressable Smoke Detector – AW-D101</h4>
<p data-start="113" data-end="187"><em data-start="113" data-end="185">(Compatible with AW-FP100 Series Addressable Fire Alarm Control Panel)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div>
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<h4 class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl"><span style="color: #222222; font-size: 30px; font-weight: bold;"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</span></h4>
</div>
</div>
</div>
<p data-start="258" data-end="411">The <strong data-start="262" data-end="300">AW-D101 Addressable Smoke Detector</strong> is an intelligent detector designed for seamless integration with AW-FP100 series fire alarm control panels.</p>
<p data-start="413" data-end="640">Each unit is assigned a unique ID address, enabling continuous monitoring of its exact location and operational status. This improves system reliability, simplifies maintenance, and enhances overall fire protection performance.</p>
<h4 data-start="642" data-end="662"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</h4>
<ul data-start="663" data-end="980">
<li data-start="663" data-end="724">
<p data-start="665" data-end="724"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Addressable-Analog Communication for precise monitoring</p>
</li>
<li data-start="725" data-end="757">
<p data-start="727" data-end="757"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low Standby Current ≤2.5mA</p>
</li>
<li data-start="758" data-end="811">
<p data-start="760" data-end="811"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Two-Wire Connection for simplified installation</p>
</li>
<li data-start="812" data-end="878">
<p data-start="814" data-end="878"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Dual Red LED Indicators (Blinking = Normal / Steady = Alarm)</p>
</li>
<li data-start="879" data-end="917">
<p data-start="881" data-end="917"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Remote Testing via Control Panel</p>
</li>
<li data-start="918" data-end="980">
<p data-start="920" data-end="980"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Separate Base Design for easy installation and servicing</p>
</li>
</ul>
<h4 data-start="1199" data-end="1232"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1234" data-end="1560">
<thead data-start="1234" data-end="1263">
<tr data-start="1234" data-end="1263">
<th class="" data-start="1234" data-end="1246" data-col-size="sm">Parameter</th>
<th class="" data-start="1246" data-end="1263" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1294" data-end="1560">
<tr data-start="1294" data-end="1327">
<td data-start="1294" data-end="1314" data-col-size="sm">Operating Voltage</td>
<td data-col-size="sm" data-start="1314" data-end="1327">18–28V DC</td>
</tr>
<tr data-start="1328" data-end="1353">
<td data-start="1328" data-end="1344" data-col-size="sm">Alarm Current</td>
<td data-col-size="sm" data-start="1344" data-end="1353">≤3 mA</td>
</tr>
<tr data-start="1354" data-end="1383">
<td data-start="1354" data-end="1372" data-col-size="sm">Standby Current</td>
<td data-col-size="sm" data-start="1372" data-end="1383">≤2.5 mA</td>
</tr>
<tr data-start="1384" data-end="1426">
<td data-start="1384" data-end="1408" data-col-size="sm">Operating Temperature</td>
<td data-start="1408" data-end="1426" data-col-size="sm">–10°C to +50°C</td>
</tr>
<tr data-start="1427" data-end="1466">
<td data-start="1427" data-end="1447" data-col-size="sm">Smoke Sensitivity</td>
<td data-col-size="sm" data-start="1447" data-end="1466">0.1 – 0.15 dB/m</td>
</tr>
<tr data-start="1467" data-end="1499">
<td data-start="1467" data-end="1488" data-col-size="sm">Standard Reference</td>
<td data-start="1488" data-end="1499" data-col-size="sm">EN 54-7</td>
</tr>
<tr data-start="1500" data-end="1527">
<td data-start="1500" data-end="1507" data-col-size="sm">Size</td>
<td data-col-size="sm" data-start="1507" data-end="1527">99.8 mm Diameter</td>
</tr>
<tr data-start="1528" data-end="1560">
<td data-start="1528" data-end="1543" data-col-size="sm">Installation</td>
<td data-start="1543" data-end="1560" data-col-size="sm">Separate base</td>
</tr>
</tbody>
</table>
</div>
</div>
<h3 data-start="1567" data-end="1614"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Conventional Smoke Detector – AW-CSD381</h3>
<p data-start="1615" data-end="1656"><em data-start="1615" data-end="1654">(For Conventional Fire Alarm Systems)</em></p>
<h4 data-start="1615" data-end="1656"><span style="color: #222222; font-size: 30px; font-weight: bold;">Product Overview</span></h4>
<p data-start="1727" data-end="1871">The <strong data-start="1731" data-end="1772">AW-CSD381 Conventional Smoke Detector</strong> uses a photoelectric sensing chamber to detect smoke particles from smoldering or flaming fires.</p>
<p data-start="1873" data-end="2032">It offers reliable early fire detection while minimizing false alarms caused by dust or steam. Ideal for small to medium-sized conventional fire alarm systems.</p>
<h4 data-start="2034" data-end="2054"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</h4>
<ul data-start="2055" data-end="2299">
<li data-start="2055" data-end="2101">
<p data-start="2057" data-end="2101"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Advanced Photoelectric Sensor Technology</p>
</li>
<li data-start="2102" data-end="2159">
<p data-start="2104" data-end="2159"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> LED Indicator (Blinking = Standby / Steady = Alarm)</p>
</li>
<li data-start="2160" data-end="2187">
<p data-start="2162" data-end="2187"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low Power Consumption</p>
</li>
<li data-start="2188" data-end="2228">
<p data-start="2190" data-end="2228"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Automatic Reset After Alarm Clears</p>
</li>
<li data-start="2229" data-end="2268">
<p data-start="2231" data-end="2268"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Easy Ceiling or Wall Installation</p>
</li>
<li data-start="2269" data-end="2299">
<p data-start="2271" data-end="2299"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Wide Panel Compatibility</p>
</li>
</ul>
<h4 data-start="2301" data-end="2334"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h4>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2336" data-end="2602">
<thead data-start="2336" data-end="2365">
<tr data-start="2336" data-end="2365">
<th class="" data-start="2336" data-end="2348" data-col-size="sm">Parameter</th>
<th class="" data-start="2348" data-end="2365" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="2396" data-end="2602">
<tr data-start="2396" data-end="2443">
<td data-start="2396" data-end="2418" data-col-size="sm">Detection Principle</td>
<td data-start="2418" data-end="2443" data-col-size="sm">Photoelectric Chamber</td>
</tr>
<tr data-start="2444" data-end="2476">
<td data-start="2444" data-end="2464" data-col-size="sm">Operating Voltage</td>
<td data-start="2464" data-end="2476" data-col-size="sm">9–28V DC</td>
</tr>
<tr data-start="2477" data-end="2507">
<td data-start="2477" data-end="2494" data-col-size="sm">Reset Function</td>
<td data-start="2494" data-end="2507" data-col-size="sm">Automatic</td>
</tr>
<tr data-start="2508" data-end="2548">
<td data-start="2508" data-end="2523" data-col-size="sm">Installation</td>
<td data-start="2523" data-end="2548" data-col-size="sm">Ceiling or Wall Mount</td>
</tr>
<tr data-start="2549" data-end="2602">
<td data-start="2549" data-end="2563" data-col-size="sm">Application</td>
<td data-start="2563" data-end="2602" data-col-size="sm">Residential, Commercial, Industrial</td>
</tr>
</tbody>
</table>
</div>
</div>
<h4 data-start="2609" data-end="2629"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</h4>
<p data-start="2631" data-end="2827"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Office Complexes<br data-start="2650" data-end="2653" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Warehouses &amp; Factories<br data-start="2678" data-end="2681" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Buildings<br data-start="2705" data-end="2708" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Malls<br data-start="2725" data-end="2728" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Universities<br data-start="2753" data-end="2756" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Facilities<br data-start="2792" data-end="2795" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e8.png" alt="🏨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hotels &amp; Hospitality Venues</p>
</div>
</div>
</div>
</div>
</div>
</div>
</article>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/smoke-detector-asenware/">Smoke Detector Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fire Alarm System GSM Module AW-GSM200 Asenware</title>
		<link>https://www.cityfireservice.com/shop/fire-alarm-system-gsm-module-aw-gsm200-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-alarm-system-gsm-module-aw-gsm200-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 09:20:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4132</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name"><strong>Fire Alarm System GSM Module AW-GSM200</strong></div>
<div class="brief">When a fire alarm or fault occurs in the fire alarm system, the GSM module will send fire alarm information to the designated person’s mobile phone via SMS. This GSM Module can connect to conventional fire alarm system, fire suppression system etc.</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-alarm-system-gsm-module-aw-gsm200-asenware/">Fire Alarm System GSM Module AW-GSM200 Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 data-start="143" data-end="186"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4e1.png" alt="📡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Asenware 4G GSM Communication Module</h4>
<p data-start="187" data-end="218">Model: AW-FP100GSM-4G For <strong data-start="227" data-end="283">AW-FP100</strong> Fire<strong data-start="227" data-end="283"> Alarm Control Panel &amp; Repeater Systems</strong></p>
<hr data-start="285" data-end="288" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="317" data-end="538">The Asenware AW-FP100GSM-4G is a dedicated 4G GSM communication module designed for use with the AW-FP100 Series Addressable Fire Alarm Control Panel, conventional repeater panels, and AW-GSM200 modules.</p>
<p data-start="540" data-end="727">When a fire alarm or fault occurs, the GSM module automatically sends an SMS notification to the designated personnel, ensuring instant alerts and faster emergency response.</p>
<hr data-start="729" data-end="732" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="755" data-end="1071">
<li data-start="755" data-end="821">
<p data-start="757" data-end="821"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Supports 4G Networks for fast and reliable communication</p>
</li>
<li data-start="822" data-end="871">
<p data-start="824" data-end="871"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Nano SIM Card Compatible for easy setup</p>
</li>
<li data-start="872" data-end="929">
<p data-start="874" data-end="929"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Multi-language SMS Notifications via PDU format</p>
</li>
<li data-start="930" data-end="998">
<p data-start="932" data-end="998"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Qualcomm Kernel ensures stability and global compatibility</p>
</li>
<li data-start="999" data-end="1071">
<p data-start="1001" data-end="1071"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Compact Design for easy integration into the fire alarm system</p>
</li>
</ul>
<hr data-start="1073" data-end="1076" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1113" data-end="1586">
<thead data-start="1113" data-end="1142">
<tr data-start="1113" data-end="1142">
<th data-start="1113" data-end="1125" data-col-size="sm">Parameter</th>
<th data-start="1125" data-end="1142" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1173" data-end="1586">
<tr data-start="1173" data-end="1207">
<td data-start="1173" data-end="1189" data-col-size="sm"><strong data-start="1175" data-end="1188">Model No.</strong></td>
<td data-start="1189" data-end="1207" data-col-size="sm">AW-FP100GSM-4G</td>
</tr>
<tr data-start="1208" data-end="1235">
<td data-start="1208" data-end="1227" data-col-size="sm"><strong data-start="1210" data-end="1226">Main Voltage</strong></td>
<td data-start="1227" data-end="1235" data-col-size="sm">5VDC</td>
</tr>
<tr data-start="1236" data-end="1282">
<td data-start="1236" data-end="1260" data-col-size="sm"><strong data-start="1238" data-end="1259">Operating Current</strong></td>
<td data-start="1260" data-end="1282" data-col-size="sm">≤5 mA (Sleep Mode)</td>
</tr>
<tr data-start="1283" data-end="1334">
<td data-start="1283" data-end="1303" data-col-size="sm"><strong data-start="1285" data-end="1302">GSM Frequency</strong></td>
<td data-start="1303" data-end="1334" data-col-size="sm">850 / 900 / 1800 / 1900 MHz</td>
</tr>
<tr data-start="1335" data-end="1378">
<td data-start="1335" data-end="1359" data-col-size="sm"><strong data-start="1337" data-end="1358">Antenna Bandwidth</strong></td>
<td data-start="1359" data-end="1378" data-col-size="sm">0.8 GHz – 3 GHz</td>
</tr>
<tr data-start="1379" data-end="1407">
<td data-start="1379" data-end="1398" data-col-size="sm"><strong data-start="1381" data-end="1397">Antenna Gain</strong></td>
<td data-start="1398" data-end="1407" data-col-size="sm">6 dBi</td>
</tr>
<tr data-start="1408" data-end="1439">
<td data-start="1408" data-end="1429" data-col-size="sm"><strong data-start="1410" data-end="1428">Antenna Length</strong></td>
<td data-start="1429" data-end="1439" data-col-size="sm">200 mm</td>
</tr>
<tr data-start="1440" data-end="1472">
<td data-start="1440" data-end="1463" data-col-size="sm"><strong data-start="1442" data-end="1462">Feed Line Length</strong></td>
<td data-start="1463" data-end="1472" data-col-size="sm">1.0 m</td>
</tr>
<tr data-start="1473" data-end="1552">
<td data-start="1473" data-end="1504" data-col-size="sm"><strong data-start="1475" data-end="1503">Environmental Conditions</strong></td>
<td data-start="1504" data-end="1552" data-col-size="sm">–5°C to +40°C<br />
5–95% RH (non-condensing)</td>
</tr>
<tr data-start="1553" data-end="1586">
<td data-start="1553" data-end="1570" data-col-size="sm"><strong data-start="1555" data-end="1569">Size (L×W)</strong></td>
<td data-start="1570" data-end="1586" data-col-size="sm">50 × 40.5 mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4f2.png" alt="📲" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Instant SMS Alerts for Fire &amp; Fault Events<br data-start="1664" data-end="1667" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> High-rise Buildings &amp; Commercial Properties<br data-start="1717" data-end="1720" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Factories &amp; Industrial Complexes<br data-start="1759" data-end="1762" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Malls &amp; Warehouses<br data-start="1796" data-end="1799" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Public Safety Facilities</p>
<div class="main">
<hr data-start="2909" data-end="2912" />
<p><strong data-start="2448" data-end="2481"><img decoding="async" class="emoji" role="img" draggable="false" src="https://s.w.org/images/core/emoji/16.0.1/svg/1f6d2.svg" alt="&#x1f6d2;" /> Available Now at City Fire</strong><br data-start="2481" data-end="2484" />✓ Trusted Quality<br data-start="2501" data-end="2504" />✓ Certified Performance<br data-start="2527" data-end="2530" />✓ Fast Nationwide Delivery</p>
</div>
<hr data-start="1846" data-end="1849" />
<p data-start="1851" data-end="1980"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> With this GSM module, your <strong data-start="1881" data-end="1929">fire alarm system becomes smarter and faster</strong>, keeping the right people informed in real time.</p>
<p>The post <a href="https://www.cityfireservice.com/shop/fire-alarm-system-gsm-module-aw-gsm200-asenware/">Fire Alarm System GSM Module AW-GSM200 Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Explosion Proof Three Infrared Flame Detector</title>
		<link>https://www.cityfireservice.com/shop/asenware-flame-detector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=asenware-flame-detector</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 13 Jan 2021 19:01:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=547</guid>

					<description><![CDATA[<div class="brief">The detector AW-FD708EX combines the three infrared band sensor and advanced flame analysis technology, to eliminate false alarm and improve detection range, and can apply to most commonplace(Pipeline, Electrostatic Paint, Printing, Warehousing, and etc.</div>
<p>The post <a href="https://www.cityfireservice.com/shop/asenware-flame-detector/">Explosion Proof Three Infrared Flame Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Explosion Proof Three Infrared Flame Detector AW-FD708EX</h4>
<p>The detector AW-FD708EX combines the three infrared band sensors and advanced flame analysis technology, to eliminate false alarms and improve detection range, and can be applied to most commonplace(Pipeline, Electrostatic Paint, Printing, Warehousing, etc.</p>
<p><strong>Product Overview:</strong></p>
<p>The Explosion Proof Three Infrared Flame Detector AW-FD708EX combines the three infrared band sensor and advanced flame analysis technology, to eliminate false alarm and improve detection range, and can apply to most commonplace(Pipeline, Electrostatic Paint, Printing, Warehousing and etc.)<br />
How To Wire The Explosion Proof Flame Detector To Fire Alarm Control Panel?</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Reliable fault diagnosis</li>
<li>Built-in high-speed, low-power, high-performance 32-bit high-precision data processing chip；</li>
<li>Adopt patented narrow band current infrared pyroelectric sensor；</li>
<li>A small fire can be detected earlier；</li>
<li>The perfect algorithm best combines flame detection and false alarm capabilities；</li>
<li>The detector is suitable for a variety of fuels；</li>
<li>It’s suitable for heavy industrial applications；</li>
<li>It’s low maintenance cost and easy to update and improve.</li>
</ul>
<table cellspacing="0">
<tbody>
<tr>
<td>
<p class="s1"><strong>Detection Range</strong></p>
</td>
<td colspan="2">
<p class="s1"><strong>Fire Source and Size</strong></p>
</td>
<td>
<p class="s1"><strong>Details</strong></p>
</td>
</tr>
<tr>
<td rowspan="7">&nbsp;</p>
<p class="s1"><strong>Maximum Distance</strong></p>
</td>
<td>
<p class="s1">N-Heptane</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">40m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Gasoline</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">35m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Diesel</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">35m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Alcohol</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">30m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Kerosene</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">35m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Methane</p>
</td>
<td>
<p class="s1">0.5&#215;0.2m</p>
</td>
<td>
<p class="s1">30m</p>
</td>
</tr>
<tr>
<td>
<p class="s1">Paper</p>
</td>
<td>
<p class="s1">0.3&#215;0.3m</p>
</td>
<td>
<p class="s1">30m</p>
</td>
</tr>
<tr>
<td>
<p class="s1"><strong>Respond Time</strong></p>
</td>
<td colspan="2">
<p class="s1">N-Heptane</p>
</td>
<td>
<p class="s1">&lt;10s</p>
</td>
</tr>
</tbody>
</table>
<p><strong>Technical Parameters:</strong></p>
<table border="0" width="747" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl65" width="257" height="26.67"><strong>Model</strong></td>
<td class="xl65" width="490">AW-FD708EX</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Main  Voltage</strong></td>
<td class="xl65">18 to 30VDC Volts</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Operating current (Relay Out)</strong></td>
<td class="xl65">Monitor:   ≦25mA                Alarm:     ≦35mA</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>(Current Loop Out)</strong></td>
<td class="xl65">Monitor:   <span class="font22">≦</span><span class="font23">30mA                Alarm:     </span><span class="font22">≦</span><span class="font23">45mA</span></td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Maximum Detection</strong><br />
<strong>Angle and Range</strong></td>
<td class="xl65">90° 40m</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Relay Output </strong></td>
<td class="xl65">Fault, Fire Alarm</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Current Loop Out</strong></td>
<td class="xl65">Fault: ≦2mA     Normal:5mA     Alarm:15mA</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Spectral Range</strong></td>
<td class="xl65">IR:3.8~5.0μM</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Explosion Proof Certification</strong></td>
<td class="xl65">ExdⅡC T6 Gb/tD A21 IP66/IP67 T80℃</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Protection Class</strong></td>
<td class="xl65">IP66 IP67</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Reset Method</strong></td>
<td class="xl65">Power off reset, Communication protocol reset, Remote control reset</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Indicator Light</strong></td>
<td class="xl65">Three (Fire, Fault, Normal)</td>
</tr>
<tr>
<td class="xl65" height="69.33"><strong>Environmental</strong></td>
<td class="xl66">Temperature range: -40 to 85°C<br />
Humidity: 0 to 96% RH, non-condensing can withstand 100% condensation humidity for a short time</td>
</tr>
<tr>
<td class="xl65" height="45.33"><strong>Materials and Colors</strong></td>
<td class="xl66">Cast  aluminum,  baking  varnish  on  the  surface  (the coating with    insulating layer), Red</td>
</tr>
<tr>
<td class="xl65" height="60"><strong>Electrical Interface</strong></td>
<td class="xl66">1 × 3/4NPT 、 M25*1.5   、 G3/4     (Adapters  can  be customized according to requirements)</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Size</strong></td>
<td class="xl65">120mm* 95mm* 85mm</td>
</tr>
<tr>
<td class="xl65" height="26.67"><strong>Weight</strong></td>
<td class="xl65">about 0.7kg</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.cityfireservice.com/shop/asenware-flame-detector/">Explosion Proof Three Infrared Flame Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>