Automatic Gas Extinguishing Panel

Original price was: ₨ 140,000.Current price is: ₨ 130,000.

AW-GEC2169 is a modern, standard-compliant gas extinguishing control panel for FM-200 and CO₂ systems. It combines fire detection, alarm & suppression control in one robust, secure & easy-to-operate panel, ensuring rapid response &reliable protection for sensitive equipment & high-risk areas
Description

🧯 Automatic Gas Extinguishing Control Panel – AW-GEC2169

The AW-GEC2169 is an automatic gas extinguishing control panel designed for FM-200 and CO₂ suppression systems. Built to comply with EN54-2, EN54-4, and EN12094-1 standards, the panel integrates fire detection, alarm, and gas release control in a single, user-friendly unit.

Its metal enclosure features an opening door with a visible glass window for safe operation. The panel monitors two alarm zones, supporting up to 16 detectors per zone, and provides comprehensive outputs for electromagnetic valves, sounders, and fire routing devices.


✨ Key Features

  • Alarm Input: Two zone signal inputs, 16 detectors per zone

  • EM Valve Output: Controls release of extinguishing gas

  • Panel Outputs: Fault output, alarm output, extinguishing signal, 24VDC output

  • Power Output: Resettable 24VDC, 200 mA current-limited

  • Automatic Power Switching: 220VAC mains and standby battery auto-switch

  • Access Control: Three levels – view, operation, settings

  • Fault Detection: Monitors input/output, system, power, ground, fuses

  • Manual Functions: Disable zones, activate evacuation, silence alarms

  • Delay Settings: Adjustable panel reset and gas release delay time

  • Security: Metal cabinet with visible glass window

  • Stability: Rigorous factory testing for safe, reliable operation


⚙️ Technical Parameters

Parameter Specification
AC Input 220VAC 50Hz ±10% / -15%
DC Output (Power Board) 24VDC (19–28V), 5VDC (4.9–5.1V)
Standby Current <450mA
Maximum Current 1.4A (except battery charging)
Batteries 2×12V / 2.3Ah sealed lead-acid gel
Battery Protection Low voltage: 21V, Replace resistance: 1.6Ω ±10%
Extinguishant Release Delay Adjustable 0–60 sec (5 sec steps)
Max Detectors per Zone 16
Max Points per Panel 32 (Detectors + MCP)
Zone Alarm Current 6–27mA
Sounder Output 200mA max
Fire/Fault Routing Output 200mA max per terminal
Communication Protocol 2-wire RS485 bus system
EOL Resistors 6.8KΩ, 1W
Environmental Class A: -5°C to 40°C, 5–95% RH, non-condensing
Terminal Blocks 12–18 AWG (0.75–2.5 mm²)
Recommended Wiring 2-core shielded cable, 12–18 AWG for interface

📌 Applications

🏢 Server Rooms & Data Centers
🏭 Industrial Equipment Rooms
🏬 Laboratories & Clean Rooms
🏥 Hospitals & Healthcare Facilities
⚡ Electrical Rooms & Switchgear Cabinets