🔥 Automatic Gas Extinguisher Control Panel
Model: AW-GEC2169
🛡️ Product Overview
The Asenware AW-GEC2169 Automatic Gas Fire Extinguisher Control Panel is designed in compliance with:
-
EN54-2: Fire detection and fire alarm systems – Control & Indicating Equipment
-
EN54-4: Fire detection and fire alarm systems – Power Supply Equipment
-
EN12094-1: Fixed firefighting systems – Electrical automatic control & delay devices
With a modern metal enclosure, glass viewing window, and user-friendly interface, the AW-GEC2169 ensures safe, stable, and reliable firefighting control.
✨ Product Features
-
🔹 Dual Zone Inputs – Two alarm zone signals, up to 16 detectors per zone
-
🔹 EM Valve Output – Controls electromagnetic valve release
-
🔹 Multiple Panel Outputs – Line fault, alarm, extinguishing signal, 24VDC
-
🔹 Automatic Power Switching – Between AC 220V and backup battery
-
🔹 Three Access Levels – View, operation, and settings
-
🔹 Real-Time Fault Detection – Input, output, power, ground, fuse monitoring
-
🔹 Manual Functions – Disable zones, evacuate, silence alarms, reset
-
🔹 Delay Time Settings – Adjustable release and reset delay (0–60s)
-
🔹 Secure Metal Cabinet – Lockable with glass window
-
🔹 Long-Term Stability – Rigorous factory testing ensures reliability
⚙️ Technical Specifications
| Parameter | Specification |
|---|---|
| AC Input | 220VAC, 50Hz (+10% / –15%) |
| DC Output | 24VDC (19–28V) & 5VDC (4.9–5.1V) |
| Standby Current | <450mA |
| Max Current (Excl. Battery Charge) | 1.4A |
| Battery Current | 1.85A (max, current-limited) |
| Auxiliary Output | 24VDC, 200mA (max) |
| Release Delay Time | 0–60s adjustable (5s steps) |
| Battery Type | 2 × 12V / 2.3Ah sealed lead-acid |
| Low-Voltage Protection | 21V |
| Max Detectors per Zone | 16 |
| Total CIE Points | 32 (detectors + MCPs) |
| Zone Alarm Current | 6mA (min) / 27mA (max) |
| Sounder Output | 200mA max |
| Routing Outputs (Fire/Fault) | 200mA each |
| Communication Protocol | 2-wire RS485 |
| EOL Resistor | 6.8KΩ, 1W |
| Recommended Wiring | 220V AC: 16AWG / Panel-Interface: 20AWG / Main Board-Interface: 28AWG |
| Fuse Ratings | Power: 3A / General: 0.2A ×5 / Main: 2A / EM Valve: 1.5A |
| Operating Temperature | –5°C to +40°C |
| Humidity | 5–95% RH, non-condensing |
| Enclosure | Metal cabinet with glass window |
| Terminal Block Rating | 12–18 AWG (0.75–2.5mm²) |
| Dimensions | [Not provided – typically depends on cabinet] |
📌 Applications
🏢 Commercial & Industrial Buildings
🏭 Gas Extinguishing Systems
🎓 Educational Institutions
🏥 Hospitals & Healthcare Facilities
📦 Warehouses & Storage Areas
🏬 Shopping Malls & Public Facilities
Available Now at City Fire
✓ Trusted Quality
✓ Certified Performance
✓ Fast Nationwide Delivery