Automatic Gas Extinguisher Control Panel AW-GEC2169
AW-GEC2169 with a new design, easy to operate, metal box opening and closing door with visible glass window, make the Panel running more safe, The automatic extinguisher control panel AW-GEC2169 is designed execute European standards of EN54-2 and EN54-4 F…
Description

πŸ”₯ Automatic Gas Extinguisher Control Panel

Model: AW-GEC2169

πŸ›‘οΈ Product Overview

The Asenware AW-GEC2169 Automatic Gas Fire Extinguisher Control Panel is designed in compliance with:

  • EN54-2: Fire detection and fire alarm systems – Control & Indicating Equipment

  • EN54-4: Fire detection and fire alarm systems – Power Supply Equipment

  • EN12094-1: Fixed firefighting systems – Electrical automatic control & delay devices

With a modern metal enclosure, glass viewing window, and user-friendly interface, the AW-GEC2169 ensures safe, stable, and reliable firefighting control.


✨ Product Features

  • πŸ”Ή Dual Zone Inputs – Two alarm zone signals, up to 16 detectors per zone

  • πŸ”Ή EM Valve Output – Controls electromagnetic valve release

  • πŸ”Ή Multiple Panel Outputs – Line fault, alarm, extinguishing signal, 24VDC

  • πŸ”Ή Automatic Power Switching – Between AC 220V and backup battery

  • πŸ”Ή Three Access Levels – View, operation, and settings

  • πŸ”Ή Real-Time Fault Detection – Input, output, power, ground, fuse monitoring

  • πŸ”Ή Manual Functions – Disable zones, evacuate, silence alarms, reset

  • πŸ”Ή Delay Time Settings – Adjustable release and reset delay (0–60s)

  • πŸ”Ή Secure Metal Cabinet – Lockable with glass window

  • πŸ”Ή Long-Term Stability – Rigorous factory testing ensures reliability


βš™οΈ Technical Specifications

Parameter Specification
AC Input 220VAC, 50Hz (+10% / –15%)
DC Output 24VDC (19–28V) & 5VDC (4.9–5.1V)
Standby Current <450mA
Max Current (Excl. Battery Charge) 1.4A
Battery Current 1.85A (max, current-limited)
Auxiliary Output 24VDC, 200mA (max)
Release Delay Time 0–60s adjustable (5s steps)
Battery Type 2 Γ— 12V / 2.3Ah sealed lead-acid
Low-Voltage Protection 21V
Max Detectors per Zone 16
Total CIE Points 32 (detectors + MCPs)
Zone Alarm Current 6mA (min) / 27mA (max)
Sounder Output 200mA max
Routing Outputs (Fire/Fault) 200mA each
Communication Protocol 2-wire RS485
EOL Resistor 6.8KΞ©, 1W
Recommended Wiring 220V AC: 16AWG / Panel-Interface: 20AWG / Main Board-Interface: 28AWG
Fuse Ratings Power: 3A / General: 0.2A Γ—5 / Main: 2A / EM Valve: 1.5A
Operating Temperature –5Β°C to +40Β°C
Humidity 5–95% RH, non-condensing
Enclosure Metal cabinet with glass window
Terminal Block Rating 12–18 AWG (0.75–2.5mmΒ²)
Dimensions [Not provided – typically depends on cabinet]

πŸ“Œ Applications

🏒 Commercial & Industrial Buildings
🏭 Gas Extinguishing Systems
πŸŽ“ Educational Institutions
πŸ₯ Hospitals & Healthcare Facilities
πŸ“¦ Warehouses & Storage Areas
🏬 Shopping Malls & Public Facilities


πŸ›’Β Available Now at City Fire
βœ“ Trusted Quality
βœ“ Certified Performance
βœ“ Fast Nationwide Delivery

Call me back

Error: Contact form not found.