<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fire Rated Cable Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<atom:link href="https://www.cityfireservice.com/product-category/fire-alarm-system/fire-rated-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cityfireservice.com/product-category/fire-alarm-system/fire-rated-cable/</link>
	<description></description>
	<lastBuildDate>Mon, 21 Sep 2026 15:55:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.cityfireservice.com/wp-content/uploads/2022/11/cropped-default-logo-32x32.png</url>
	<title>Fire Rated Cable Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<link>https://www.cityfireservice.com/product-category/fire-alarm-system/fire-rated-cable/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Linear Detector Interface Module</title>
		<link>https://www.cityfireservice.com/products/linear-detector-interface-module/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=linear-detector-interface-module</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 17 May 2026 16:29:35 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7506</guid>

					<description><![CDATA[<p>The Asenware AW-D401 Linear Detector Interface Module and AW-D402 Linear Detector Endline Module are used together in linear beam smoke detector systems to provide reliable alarm signal processing, circuit supervision, and fault monitoring for conventional fire alarm installations in large and high-ceiling areas.</p>
<p>The post <a href="https://www.cityfireservice.com/products/linear-detector-interface-module/">Linear Detector Interface Module</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p data-section-id="1kwx1sz" data-start="693" data-end="738">The Asenware AW-D401 and AW-D402 are accessory modules used with conventional beam smoke detectors (linear smoke detectors). These modules help interface and supervise the beam detector system within a fire alarm installation.</p>
<h3 data-section-id="1kwx1sz" data-start="693" data-end="738">AW-D401 — Linear Detector Interface Module</h3>
<h4 data-section-id="d8hsak" data-start="742" data-end="760">Main Functions</h4>
<ul data-start="761" data-end="1034">
<li data-section-id="1twfjih" data-start="761" data-end="826">Interfaces beam detector signals with fire alarm control panels</li>
<li data-section-id="1a852dj" data-start="827" data-end="865">Processes alarm and fault conditions</li>
<li data-section-id="30b94v" data-start="866" data-end="928">Provides relay outputs for:
<ul data-start="898" data-end="928">
<li data-section-id="nr14eb" data-start="898" data-end="910">Fire alarm</li>
<li data-section-id="7rbpp6" data-start="913" data-end="928">Fault/trouble</li>
</ul>
</li>
<li data-section-id="1oqr46u" data-start="929" data-end="973">Supports detector alignment and monitoring</li>
<li data-section-id="1swh0ca" data-start="974" data-end="1034">Improves system stability for long-distance beam detection</li>
</ul>
<h3 data-section-id="1p927wt" data-start="228" data-end="247">Product Overview</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="249" data-end="488">
<thead data-start="249" data-end="288">
<tr data-start="249" data-end="288">
<th class="last:pe-10" data-start="249" data-end="257" data-col-size="sm">Model</th>
<th class="last:pe-10" data-start="257" data-end="271" data-col-size="sm">Description</th>
<th class="last:pe-10" data-start="271" data-end="288" data-col-size="md">Main Function</th>
</tr>
</thead>
<tbody data-start="303" data-end="488">
<tr data-start="303" data-end="394">
<td data-start="303" data-end="313" data-col-size="sm">AW-D401</td>
<td data-col-size="sm" data-start="313" data-end="348">Linear Detector Interface Module</td>
<td data-col-size="md" data-start="348" data-end="394">Signal processing and fire alarm interface</td>
</tr>
<tr data-start="395" data-end="488">
<td data-start="395" data-end="405" data-col-size="sm">AW-D402</td>
<td data-col-size="sm" data-start="405" data-end="438">Linear Detector Endline Module</td>
<td data-col-size="md" data-start="438" data-end="488">End-of-line supervision and circuit monitoring</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="490" data-end="571">These modules are typically used together with projected beam smoke detectors in:</p>
<ul data-start="572" data-end="686">
<li data-section-id="tniev2" data-start="572" data-end="584">Warehouses</li>
<li data-section-id="c421a2" data-start="585" data-end="596">Factories</li>
<li data-section-id="wxb0kj" data-start="597" data-end="613">Shopping malls</li>
<li data-section-id="1182i8l" data-start="614" data-end="632">Mosques/churches</li>
<li data-section-id="1se39kd" data-start="633" data-end="642">Atriums</li>
<li data-section-id="32979p" data-start="643" data-end="667">High-ceiling buildings</li>
<li data-section-id="56nng0" data-start="668" data-end="686">Aircraft hangars</li>
</ul>
<hr data-start="688" data-end="691" />
<h3 data-section-id="1exvra3" data-start="1036" data-end="1056">Typical Features</h3>
<ul data-start="1057" data-end="1271">
<li data-section-id="xyh5ly" data-start="1057" data-end="1103">Conventional fire alarm system compatibility</li>
<li data-section-id="6qx1g1" data-start="1104" data-end="1155">LED indication for:
<ul data-start="1128" data-end="1155">
<li data-section-id="1753qlz" data-start="1128" data-end="1135">Power</li>
<li data-section-id="16yowmz" data-start="1138" data-end="1145">Alarm</li>
<li data-section-id="170xgle" data-start="1148" data-end="1155">Fault</li>
</ul>
</li>
<li data-section-id="1vx0k6u" data-start="1156" data-end="1178">Resettable operation</li>
<li data-section-id="11euyj8" data-start="1179" data-end="1234">Stable communication between transmitter and receiver</li>
<li data-section-id="7peqsk" data-start="1235" data-end="1271">Easy DIN rail or wall installation</li>
</ul>
<h3 data-section-id="xx0hya" data-start="1273" data-end="1296">Common Applications</h3>
<ul data-start="1297" data-end="1414">
<li data-section-id="18htyel" data-start="1297" data-end="1313">Long corridors</li>
<li data-section-id="tniev2" data-start="1314" data-end="1326">Warehouses</li>
<li data-section-id="3wjyu2" data-start="1327" data-end="1340">Auditoriums</li>
<li data-section-id="42f3ho" data-start="1341" data-end="1364">Industrial facilities</li>
<li data-section-id="ig13b0" data-start="1365" data-end="1414">High roofs where spot detectors are impractical</li>
</ul>
<hr data-start="1416" data-end="1419" />
<h3 data-section-id="1453ttw" data-start="1421" data-end="1464">AW-D402 — Linear Detector Endline Module</h3>
<h4 data-section-id="d8hsak" data-start="1468" data-end="1486">Main Functions</h4>
<ul data-start="1487" data-end="1691">
<li data-section-id="wc5r4c" data-start="1487" data-end="1520">Provides end-of-line monitoring</li>
<li data-section-id="12wrdmg" data-start="1521" data-end="1550">Supervises wiring integrity</li>
<li data-section-id="18vooqu" data-start="1551" data-end="1590">Detects open/short circuit conditions</li>
<li data-section-id="1le1an7" data-start="1591" data-end="1638">Ensures proper beam detector loop supervision</li>
<li data-section-id="1p17t7e" data-start="1639" data-end="1691">Used at the last point of detector wiring circuits</li>
</ul>
<h4 data-section-id="1exvra3" data-start="1693" data-end="1713">Typical Features</h4>
<ul data-start="1714" data-end="1874">
<li data-section-id="10eicef" data-start="1714" data-end="1737">Compact module design</li>
<li data-section-id="hxg984" data-start="1738" data-end="1776">Improves fault detection reliability</li>
<li data-section-id="j4cv9" data-start="1777" data-end="1829">Compatible with conventional beam detector systems</li>
<li data-section-id="1tew6cd" data-start="1830" data-end="1874">Simplifies maintenance and troubleshooting</li>
</ul>
<hr data-start="1876" data-end="1879" />
<h4 data-section-id="vkt6ck" data-start="1881" data-end="1910">Typical System Arrangement</h4>
<p data-start="1912" data-end="1972">A beam detector system using these modules usually includes:</p>
<ol data-start="1974" data-end="2110">
<li data-section-id="1ohil6q" data-start="1974" data-end="2002">Beam detector transmitter</li>
<li data-section-id="8yomcx" data-start="2003" data-end="2028">Beam detector receiver</li>
<li data-section-id="1wy5dot" data-start="2029" data-end="2056">AW-D401 interface module</li>
<li data-section-id="hu4xv1" data-start="2057" data-end="2082">AW-D402 endline module</li>
<li data-section-id="25c9no" data-start="2083" data-end="2110">Fire alarm control panel</li>
</ol>
<h3 data-section-id="1ruj8lp" data-start="2112" data-end="2135">Operating Principle</h3>
<ul data-start="2136" data-end="2380">
<li data-section-id="1bg4q6l" data-start="2136" data-end="2221">The beam detector continuously monitors infrared beam interruption caused by smoke.</li>
<li data-section-id="1cibhjs" data-start="2222" data-end="2305">AW-D401 converts detector conditions into alarm/fault outputs for the fire panel.</li>
<li data-section-id="e4qeo3" data-start="2306" data-end="2380">AW-D402 supervises the circuit termination and ensures wiring integrity.</li>
</ul>
<hr data-start="2382" data-end="2385" />
<h4 data-section-id="r0ul9p" data-start="2387" data-end="2425">Advantages of Linear Beam Detection</h4>
<ul data-start="2426" data-end="2570">
<li data-section-id="nq1g9n" data-start="2426" data-end="2451">Covers large open areas</li>
<li data-section-id="abv4iz" data-start="2452" data-end="2478">Fewer detectors required</li>
<li data-section-id="1s0jcw8" data-start="2479" data-end="2504">Ideal for high ceilings</li>
<li data-section-id="1fqj2sd" data-start="2505" data-end="2529">Lower maintenance cost</li>
<li data-section-id="d5mw64" data-start="2530" data-end="2570">Faster installation in large buildings</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/linear-detector-interface-module/">Linear Detector Interface Module</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fire Resistant Cable Asenware</title>
		<link>https://www.cityfireservice.com/products/fire-resistant-cable-asenware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-resistant-cable-asenware</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 10:37:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=4160</guid>

					<description><![CDATA[<div class="prodetacr_name">
<div class="name">
<div class="name">
<p class="name"><strong>Fire Resistant Cable 2×1.5</strong></p>
<div class="desc">AW-FPC2×1.5 Fire Resistant Cable is used where critical circuits need to function to keep safety equipment running even when exposed to extreme heat or fire...</div>
</div>
<div><span style="color: #ff6600;"><strong>Price 280/- Per Meter</strong></span></div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/products/fire-resistant-cable-asenware/">Fire Resistant Cable Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="art_bor">
<div class="main">
<div class="art_title">
<div class="art_bor">
<div class="main">
<div class="art_title">
<h4 data-start="131" data-end="167"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> UL Listed Fire Resistant Cable</h4>
<p data-start="168" data-end="206">Model: AW-FPLR2X1.5 (16 AWG)</p>
<hr data-start="208" data-end="211" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6e1.png" alt="🛡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="240" data-end="610">The AW-FPC 2-core 1.5mm Fire Resistant Cable is designed for critical safety circuits that must remain operational during extreme heat and fire conditions. With multi-stranded tinned copper conductors, aluminum foil shielding, and durable fire-resistant PVC covering, this cable ensures reliable performance and compliance in life-safety installations.</p>
<p data-start="612" data-end="761">It is ideal for fire alarm systems, emergency lighting, smoke control, and firefighting equipment wiring where uninterrupted function is vital.</p>
<hr data-start="763" data-end="766" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="789" data-end="1331">
<li data-start="789" data-end="864">
<p data-start="791" data-end="864"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Resistant – Maintains circuit integrity during fire exposure</p>
</li>
<li data-start="865" data-end="957">
<p data-start="867" data-end="957"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> High-Quality Conductor – Multi-stranded tinned copper for flexibility &amp; durability</p>
</li>
<li data-start="958" data-end="1023">
<p data-start="960" data-end="1023"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Reliable Insulation – AV thickness 0.38mm (min. 0.33mm)</p>
</li>
<li data-start="1024" data-end="1102">
<p data-start="1026" data-end="1102"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shielded Protection – Aluminum foil winding for reduced interference</p>
</li>
<li data-start="1103" data-end="1174">
<p data-start="1105" data-end="1174"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Color-Coded Core Wires – Easy identification and installation</p>
</li>
<li data-start="1175" data-end="1255">
<p data-start="1177" data-end="1255"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable Outer Sheath – Red UL105° PVC, fire-retardant and long-lasting</p>
</li>
<li data-start="1256" data-end="1331">
<p data-start="1258" data-end="1331"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Complies with Safety Standards – Engineered for critical circuits</p>
</li>
</ul>
<hr data-start="1333" data-end="1336" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1373" data-end="1996">
<thead data-start="1373" data-end="1402">
<tr data-start="1373" data-end="1402">
<th data-start="1373" data-end="1385" data-col-size="sm">Parameter</th>
<th data-start="1385" data-end="1402" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1433" data-end="1996">
<tr data-start="1433" data-end="1470">
<td data-start="1433" data-end="1445" data-col-size="sm"><strong data-start="1435" data-end="1444">Model</strong></td>
<td data-start="1445" data-end="1470" data-col-size="md">AW-FPLR2X1.5 (16 AWG)</td>
</tr>
<tr data-start="1471" data-end="1511">
<td data-start="1471" data-end="1482" data-col-size="sm"><strong data-start="1473" data-end="1481">Type</strong></td>
<td data-start="1482" data-end="1511" data-col-size="md">Multi-stranded fire cable</td>
</tr>
<tr data-start="1512" data-end="1569">
<td data-start="1512" data-end="1528" data-col-size="sm"><strong data-start="1514" data-end="1527">Conductor</strong></td>
<td data-start="1528" data-end="1569" data-col-size="md">Tinned copper stranded, Ø max. 0.50mm</td>
</tr>
<tr data-start="1570" data-end="1621">
<td data-start="1570" data-end="1608" data-col-size="sm"><strong data-start="1572" data-end="1607">Max Conductor Resistance (20°C)</strong></td>
<td data-start="1608" data-end="1621" data-col-size="md">13.7 Ω/km</td>
</tr>
<tr data-start="1622" data-end="1676">
<td data-start="1622" data-end="1649" data-col-size="sm"><strong data-start="1624" data-end="1648">Insulation Thickness</strong></td>
<td data-start="1649" data-end="1676" data-col-size="md">AV: 0.38mm, Min: 0.33mm</td>
</tr>
<tr data-start="1677" data-end="1716">
<td data-start="1677" data-end="1693" data-col-size="sm"><strong data-start="1679" data-end="1692">Core Wire</strong></td>
<td data-start="1693" data-end="1716" data-col-size="md">Color-coded with ID</td>
</tr>
<tr data-start="1717" data-end="1752">
<td data-start="1717" data-end="1733" data-col-size="sm"><strong data-start="1719" data-end="1732">Stranding</strong></td>
<td data-start="1733" data-end="1752" data-col-size="md">2-core stranded</td>
</tr>
<tr data-start="1753" data-end="1828">
<td data-start="1753" data-end="1771" data-col-size="sm"><strong data-start="1755" data-end="1770">Ground Wire</strong></td>
<td data-start="1771" data-end="1828" data-col-size="md">Tinned copper stranded, Ø max. 0.26mm (single strand)</td>
</tr>
<tr data-start="1829" data-end="1896">
<td data-start="1829" data-end="1853" data-col-size="sm"><strong data-start="1831" data-end="1852">Shielding/Winding</strong></td>
<td data-start="1853" data-end="1896" data-col-size="md">Aluminum foil (conductive layer inward)</td>
</tr>
<tr data-start="1897" data-end="1946">
<td data-start="1897" data-end="1918" data-col-size="sm"><strong data-start="1899" data-end="1917">Outer Covering</strong></td>
<td data-start="1918" data-end="1946" data-col-size="md">Red PVC (UL105° PVC-55P)</td>
</tr>
<tr data-start="1947" data-end="1996">
<td data-start="1947" data-end="1965" data-col-size="sm"><strong data-start="1949" data-end="1964">Application</strong></td>
<td data-start="1965" data-end="1996" data-col-size="md">Fire alarm &amp; safety systems</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p data-start="2025" data-end="2192"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f6a8.png" alt="🚨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Alarm Systems<br data-start="2046" data-end="2049" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4a1.png" alt="💡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Emergency Lighting Circuits<br data-start="2079" data-end="2082" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4a8.png" alt="💨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Smoke &amp; Ventilation Systems<br data-start="2112" data-end="2115" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f525.png" alt="🔥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Suppression Equipment Wiring<br data-start="2151" data-end="2154" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Commercial &amp; Industrial Buildings</p>
<div class="main">
<hr data-start="2909" data-end="2912" />
<p><strong data-start="2448" data-end="2481"><img decoding="async" class="emoji" role="img" draggable="false" src="https://s.w.org/images/core/emoji/16.0.1/svg/1f6d2.svg" alt="&#x1f6d2;" /> Available Now at City Fire</strong><br data-start="2481" data-end="2484" />✓ Trusted Quality<br data-start="2501" data-end="2504" />✓ Certified Performance<br data-start="2527" data-end="2530" />✓ Fast Nationwide Delivery</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.cityfireservice.com/products/fire-resistant-cable-asenware/">Fire Resistant Cable Asenware</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Linear Heat Detection Cable LHDC</title>
		<link>https://www.cityfireservice.com/products/linear-heat-detection-cable/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=linear-heat-detection-cable</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 13 Jan 2021 18:59:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=546</guid>

					<description><![CDATA[<div class="prodetacr_jj">Asenware offers early fire detection along cable runs, machinery, or open areas, making it ideal for industrial, utility, and high-risk environments where traditional point detectors are impractical.</div>
<div>Price: Per Meter</div>
<p>The post <a href="https://www.cityfireservice.com/products/linear-heat-detection-cable/">Linear Heat Detection Cable LHDC</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 data-start="153" data-end="196">Linear Heat Detection System – LHDC</h3>
<h4 data-start="86" data-end="111"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50e.png" alt="🔎" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</h4>
<p data-start="112" data-end="386">The <strong data-start="116" data-end="153">Linear Heat Detector Cable (LHDC)</strong> provides continuous fire and heat detection along its entire length. Unlike point detectors, it can sense elevated temperatures anywhere along the cable path, making it ideal for areas where conventional detectors are impractical.</p>
<p data-start="388" data-end="754">When the ambient temperature reaches the cable’s fixed activation point, the heat-sensitive insulation softens, allowing the internal conductors to make contact. This creates an electrical short that triggers the fire alarm system. LHDC is available with activation temperatures of <strong data-start="670" data-end="678">88°C</strong> and <strong data-start="683" data-end="692">105°C</strong>, suitable for various industrial and commercial applications.</p>
<hr data-start="756" data-end="759" />
<h4 data-start="761" data-end="781"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Composition</h4>
<ol data-start="783" data-end="1103">
<li data-start="783" data-end="924">
<p data-start="786" data-end="810"><strong data-start="786" data-end="806">Steel Conductors</strong> –</p>
<ul data-start="814" data-end="924">
<li data-start="814" data-end="850">
<p data-start="816" data-end="850">Steel: Provides tensile strength</p>
</li>
<li data-start="854" data-end="891">
<p data-start="856" data-end="891">Copper: Ensures high conductivity</p>
</li>
<li data-start="895" data-end="924">
<p data-start="897" data-end="924">Tin: Corrosion resistance</p>
</li>
</ul>
</li>
<li data-start="926" data-end="1024">
<p data-start="929" data-end="1024"><strong data-start="929" data-end="948">Protective Tape</strong> – Heat-sensitive insulation that activates at a predetermined temperature</p>
</li>
<li data-start="1026" data-end="1103">
<p data-start="1029" data-end="1103"><strong data-start="1029" data-end="1045">Outer Jacket</strong> – Available in 4 types to suit environmental conditions</p>
</li>
</ol>
<hr data-start="1105" data-end="1108" />
<h4 data-start="1110" data-end="1128"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Advantages</h4>
<ul data-start="1130" data-end="1458">
<li data-start="1130" data-end="1175">
<p data-start="1132" data-end="1175">Detects heat at any point along the cable</p>
</li>
<li data-start="1176" data-end="1200">
<p data-start="1178" data-end="1200">Minimal false alarms</p>
</li>
<li data-start="1201" data-end="1242">
<p data-start="1203" data-end="1242">Easy installation and low maintenance</p>
</li>
<li data-start="1243" data-end="1288">
<p data-start="1245" data-end="1288">Can be installed near high-risk equipment</p>
</li>
<li data-start="1289" data-end="1362">
<p data-start="1291" data-end="1362">Resistant to corrosion, chemicals, moisture, and extreme temperatures</p>
</li>
<li data-start="1363" data-end="1388">
<p data-start="1365" data-end="1388">Long operational life</p>
</li>
<li data-start="1389" data-end="1458">
<p data-start="1391" data-end="1458">Compatible with domestic and international fire alarm controllers                                                                      <img fetchpriority="high" decoding="async" class="" src="https://www.asenware.com/u_file/images/21_10_19/29487f193a.jpg" alt="LINEAR HEAT DETECTOR CABLE" width="1044" height="348" /></p>
</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/linear-heat-detection-cable/">Linear Heat Detection Cable LHDC</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
