<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Conventional Fire Alarm Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<atom:link href="https://www.cityfireservice.com/product-category/fire-alarm-system/conventional-fire-alarm/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cityfireservice.com/product-category/fire-alarm-system/conventional-fire-alarm/</link>
	<description></description>
	<lastBuildDate>Tue, 22 Sep 2026 06:07:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.cityfireservice.com/wp-content/uploads/2022/11/cropped-default-logo-32x32.png</url>
	<title>Conventional Fire Alarm Archives | Fire Fighting Equipment | Fire Safety Equipment</title>
	<link>https://www.cityfireservice.com/product-category/fire-alarm-system/conventional-fire-alarm/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Conventional Smoke &#038; Heat Detector</title>
		<link>https://www.cityfireservice.com/products/conventional-smoke-heat-detector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-smoke-heat-detector</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 10:48:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7992</guid>

					<description><![CDATA[<p>Reliable <strong data-start="3130" data-end="3163">dual smoke and heat detection</strong> for addressable and conventional fire alarm systems. With <strong data-start="3225" data-end="3290">low standby current, dual LED visibility, and EN54 compliance</strong>, these detectors are ideal for protecting <strong data-start="3333" data-end="3347">open areas</strong> with precise and dependable fire detection.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-heat-detector/">Conventional Smoke &#038; Heat Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Conventional Smoke &amp; Heat Detector – AW-D138C</h3>
<h4>Compatible with Conventional Fire Alarm Control Panels</h4>
<h4>Product Overview</h4>
<p class="isSelectedEnd">The <strong>AW-D138C Conventional Smoke &amp; Heat Detector</strong> combines <strong>photoelectric smoke detection</strong> with <strong>fixed temperature and rate-of-rise heat sensing</strong>, providing dependable fire detection for conventional fire alarm systems.</p>
<p class="isSelectedEnd">Designed for indoor open-area protection, the detector features highly sensitive optical sensing, reliable thermal detection, and <strong>360° visible LED indication</strong> for rapid alarm recognition. Its two-wire connection enables simple installation with most conventional fire alarm control panels.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Product Features</h4>
<ul data-spread="false">
<li>Conventional Fire Alarm System Compatible</li>
<li>Photoelectric Smoke Detection</li>
<li>Fixed Temperature &amp; Rate-of-Rise Heat Detection</li>
<li>Two-Wire Zone Connection</li>
<li>Low Standby Current</li>
<li>Dual 360° LED Alarm Indicators</li>
<li>Reliable Open Area Detection</li>
<li>Durable ABS Housing</li>
<li>Easy Installation and Maintenance</li>
<li>High Performance and Long Service Life</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>Model</td>
<td>AW-D138C</td>
</tr>
<tr>
<td>System Type</td>
<td>Conventional</td>
</tr>
<tr>
<td>Operating Voltage</td>
<td>9–28V DC (Zone)</td>
</tr>
<tr>
<td>Monitoring Current</td>
<td>≤120 µA</td>
</tr>
<tr>
<td>Alarm Current</td>
<td>≤20 mA @ 24V DC</td>
</tr>
<tr>
<td>Smoke Sensitivity</td>
<td>0.18–0.30 dB/m</td>
</tr>
<tr>
<td>Heat Alarm</td>
<td>57°C (135°F) A2R</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>–10°C to +50°C</td>
</tr>
<tr>
<td>Relative Humidity</td>
<td>5–95% RH (Non-condensing)</td>
</tr>
<tr>
<td>Housing Material</td>
<td>ABS, White</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Ø100 × 55.7 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 120 g</td>
</tr>
<tr>
<td>Protection Area</td>
<td>60 m² (≤6 m ceiling) / 80 m² (6–12 m ceiling)</td>
</tr>
<tr>
<td>Application</td>
<td>Indoor</td>
</tr>
<tr>
<td>Compatible Panel</td>
<td>Conventional Fire Alarm Control Panels</td>
</tr>
</tbody>
</table>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Office Buildings</li>
<li>Shopping Centres</li>
<li>Warehouses</li>
<li>Industrial Facilities</li>
<li>Hotels</li>
<li>Hospitals</li>
<li>Schools &amp; Universities</li>
<li>Residential Complexes</li>
<li>Retail Stores</li>
<li>Commercial Buildings</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Advantages</h4>
<ul data-spread="false">
<li>Dual smoke and heat sensing for improved fire detection</li>
<li>Reduced nuisance alarms compared to single-sensor detectors</li>
<li>Reliable performance in a wide range of environments</li>
<li>Quick installation with conventional fire alarm systems</li>
<li>Cost-effective protection for commercial, industrial, and residential applications</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-heat-detector/">Conventional Smoke &#038; Heat Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Heat Detector</title>
		<link>https://www.cityfireservice.com/products/conventional-heat-detector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-heat-detector</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 10:40:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7987</guid>

					<description><![CDATA[<p>With dual detection technology, low standby current, and clear LED indicators, these detectors ensure accurate monitoring and fast response in both addressable and conventional fire alarm systems.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-heat-detector/">Conventional Heat Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Conventional Heat Detector – AW-CTD382</h3>
<h4>For Conventional Fire Alarm Systems</h4>
<h4>Product Overview</h4>
<p class="isSelectedEnd">The <strong>AW-CTD382 Conventional Heat Detector</strong> provides reliable open-area fire detection using <strong>dual sensing technology</strong>, combining <strong>Rate-of-Rise</strong> and <strong>Fixed Temperature</strong> detection for enhanced protection.</p>
<p class="isSelectedEnd">Designed for compatibility with most conventional fire alarm control panels, it delivers dependable performance in environments where smoke detectors may be affected by dust, steam, or airborne contaminants.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Product Features</h4>
<ul data-spread="false">
<li>Conventional Fire Alarm System Compatible</li>
<li>Dual Detection Technology
<ul data-spread="false">
<li>Rate-of-Rise Detection</li>
<li>Fixed Temperature Detection</li>
</ul>
</li>
<li>Dual LED Indicators with 360° Visibility</li>
<li>Standby Indication (LED Flashes Every 6 Seconds)</li>
<li>Alarm Indication (LED Latches ON)</li>
<li>Automatic Reset via Momentary Power Interruption</li>
<li>Wide Compatibility with Conventional Fire Alarm Panels</li>
<li>Easy Installation and Maintenance</li>
<li>Reliable and Stable Performance</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>Model</td>
<td>AW-CTD382</td>
</tr>
<tr>
<td>Detection Method</td>
<td>Rate-of-Rise &amp; Fixed Temperature</td>
</tr>
<tr>
<td>System Type</td>
<td>Conventional</td>
</tr>
<tr>
<td>LED Indication</td>
<td>Flash (Standby) / Latch (Alarm)</td>
</tr>
<tr>
<td>Reset Method</td>
<td>Momentary Power Interruption</td>
</tr>
<tr>
<td>Application</td>
<td>Open Area Heat Detection</td>
</tr>
</tbody>
</table>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Office Buildings</li>
<li>Hotels &amp; Hospitality Venues</li>
<li>Factories &amp; Industrial Plants</li>
<li>Warehouses</li>
<li>Shopping Centres</li>
<li>Schools &amp; Universities</li>
<li>Residential Buildings</li>
<li>Commercial Facilities</li>
<li>Electrical Rooms</li>
<li>Parking Garages</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Advantages</h4>
<ul data-spread="false">
<li>Fast response to rapid temperature rise</li>
<li>Reliable fixed temperature protection</li>
<li>Reduces nuisance alarms in dusty or humid environments</li>
<li>Simple installation and maintenance</li>
<li>Suitable for residential, commercial, and industrial applications</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-heat-detector/">Conventional Heat Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Waterproof Sounder Strobe</title>
		<link>https://www.cityfireservice.com/products/conventional-waterproof-sounder-strobe/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-waterproof-sounder-strobe</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 10:32:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7983</guid>

					<description><![CDATA[<p>Weatherproof audio-visual alarm device designed for conventional fire alarm systems. it provides effective emergency warning in both indoor and outdoor environments. Its IP65-rated enclosure ensures reliable performance in harsh weather and industrial conditions.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-waterproof-sounder-strobe/">Conventional Waterproof Sounder Strobe</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Conventional Waterproof Sounder Strobe – AW-D150C</h3>
<h4>Reliable Audible &amp; Visual Fire Alarm Notification</h4>
<p class="isSelectedEnd">The <strong>Asenware AW-D150C Conventional Waterproof Sounder Strobe</strong> is a high-performance audio-visual notification device designed for conventional fire alarm systems. It combines a powerful electronic sounder with a high-intensity LED strobe to provide rapid and effective emergency warning in commercial, industrial, and outdoor environments.</p>
<p class="isSelectedEnd">Its rugged <strong>IP65 weatherproof enclosure</strong> ensures dependable performance under harsh environmental conditions, making it suitable for both indoor and outdoor fire alarm applications.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Product Features</h4>
<ul data-spread="false">
<li>Conventional Fire Alarm System Compatible</li>
<li>Combined Audible &amp; Visual Alarm</li>
<li>High-Intensity LED Strobe Light</li>
<li>Powerful Sound Output (≥105 dB @ 1 m)</li>
<li>Weatherproof IP65 Construction</li>
<li>Suitable for Indoor &amp; Outdoor Installation</li>
<li>Easy Installation &amp; Maintenance</li>
<li>Durable UV-Resistant Housing</li>
<li>Reliable Performance for Critical Fire Alarm Applications</li>
<li>EN54-3 Compliant</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>Model</td>
<td>AW-D150C</td>
</tr>
<tr>
<td>Device Type</td>
<td>Conventional Waterproof Sounder Strobe</td>
</tr>
<tr>
<td>System Type</td>
<td>Conventional Fire Alarm System</td>
</tr>
<tr>
<td>Protection Rating</td>
<td>IP65</td>
</tr>
<tr>
<td>Sound Output</td>
<td>≥105 dB @ 1 m</td>
</tr>
<tr>
<td>Visual Indicator</td>
<td>High-Intensity LED Strobe</td>
</tr>
<tr>
<td>Installation</td>
<td>Indoor &amp; Outdoor</td>
</tr>
<tr>
<td>Compliance</td>
<td>EN54-3</td>
</tr>
<tr>
<td>Compatibility</td>
<td>Conventional Fire Alarm Control Panels</td>
</tr>
<tr>
<td>Brand</td>
<td>Asenware</td>
</tr>
<tr>
<td>Country of Origin</td>
<td>China</td>
</tr>
</tbody>
</table>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Commercial Buildings</li>
<li>Industrial Facilities</li>
<li>Warehouses</li>
<li>Pump Rooms</li>
<li>Manufacturing Plants</li>
<li>Shopping Centres</li>
<li>Hospitals</li>
<li>Hotels</li>
<li>Power Plants</li>
<li>Outdoor Fire Protection Systems</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-waterproof-sounder-strobe/">Conventional Waterproof Sounder Strobe</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Smoke Detector</title>
		<link>https://www.cityfireservice.com/products/conventional-smoke-detector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-smoke-detector</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 10:02:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7976</guid>

					<description><![CDATA[<p>Designed for seamless integration with addressable and conventional control panels, these detectors ensure accurate monitoring, low power consumption, and dependable performance in residential, commercial, and industrial environments.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-detector/">Conventional Smoke Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Conventional Smoke Detector – AW-CSD381</h3>
<h4>For Conventional Fire Alarm Systems</h4>
<h4>Product Overview</h4>
<p class="isSelectedEnd">The <strong>AW-CSD381 Conventional Smoke Detector</strong> utilizes advanced <strong>photoelectric sensing technology</strong> to detect visible smoke generated by smoldering and flaming fires.</p>
<p class="isSelectedEnd">Designed for reliable early warning, the detector minimizes nuisance alarms caused by dust or steam while delivering dependable protection for residential, commercial, and industrial applications. It is compatible with most conventional fire alarm control panels.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Key Features</h4>
<ul data-spread="false">
<li>Advanced Photoelectric Detection Technology</li>
<li>Conventional Fire Alarm System Compatibility</li>
<li>Low Power Consumption</li>
<li>Dual LED Status Indicator
<ul data-spread="false">
<li>Flashing: Standby</li>
<li>Steady ON: Alarm</li>
</ul>
</li>
<li>Automatic Reset After Alarm Clears</li>
<li>Ceiling or Wall Mount Installation</li>
<li>Easy Installation and Maintenance</li>
<li>Wide Compatibility with Conventional Fire Alarm Panels</li>
<li>Reliable and Stable Performance</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>Model</td>
<td>AW-CSD381</td>
</tr>
<tr>
<td>Detection Principle</td>
<td>Photoelectric Chamber</td>
</tr>
<tr>
<td>Operating Voltage</td>
<td>9–28V DC</td>
</tr>
<tr>
<td>Reset Function</td>
<td>Automatic</td>
</tr>
<tr>
<td>Installation</td>
<td>Ceiling or Wall Mount</td>
</tr>
<tr>
<td>Application</td>
<td>Residential, Commercial &amp; Industrial</td>
</tr>
<tr>
<td>System Type</td>
<td>Conventional</td>
</tr>
</tbody>
</table>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Office Complexes</li>
<li>Warehouses &amp; Factories</li>
<li>Residential Buildings</li>
<li>Shopping Malls</li>
<li>Schools &amp; Universities</li>
<li>Hospitals &amp; Healthcare Facilities</li>
<li>Hotels &amp; Hospitality Venues</li>
<li>Retail Stores</li>
<li>Commercial Buildings</li>
<li>Public Facilities</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-detector/">Conventional Smoke Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Manual Call Point</title>
		<link>https://www.cityfireservice.com/products/conventional-manual-call-point/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-manual-call-point</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 09:56:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7973</guid>

					<description><![CDATA[<p><strong>AW-D135C Conventional Manual Call Point</strong> is designed for use with conventional two-wire fire alarm systems. When activated, it immediately sends an alarm signal to the fire alarm control panel, providing fast manual fire reporting and emergency notification.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-manual-call-point/">Conventional Manual Call Point</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Conventional Manual Call Point – AW-D135C</h3>
<h4>For Two-Wire Conventional Fire Alarm Systems</h4>
<h4>Product Overview</h4>
<p class="isSelectedEnd">The <strong>AW-D135C Conventional Manual Call Point</strong> is designed for use with conventional two-wire fire alarm systems. When activated, it immediately sends an alarm signal to the fire alarm control panel, providing fast manual fire reporting and emergency notification.</p>
<p class="isSelectedEnd">The unit incorporates a <strong>red LED status indicator</strong>, which flashes during normal monitoring and remains continuously illuminated when in alarm condition. A dedicated reset key enables quick restoration after activation without replacing any components.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Key Features</h4>
<ul data-spread="false">
<li>Conventional Two-Wire Operation</li>
<li>EN54 Standard Compliant</li>
<li>Resettable Manual Call Point</li>
<li>Reset Key Included</li>
<li>LED Status Indicator
<ul data-spread="false">
<li>Flashing: Normal</li>
<li>Steady ON: Alarm</li>
</ul>
</li>
<li>Semi-Flush or Surface Mounting</li>
<li>Durable Flame-Retardant ABS Housing</li>
<li>Easy Installation and Maintenance</li>
<li>Reliable Operation</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>System Type</td>
<td>Conventional</td>
</tr>
<tr>
<td>Operating Voltage</td>
<td>24V DC (via Control Panel)</td>
</tr>
<tr>
<td>Installation</td>
<td>Semi-Recessed or Surface Mounted</td>
</tr>
<tr>
<td>Reset Method</td>
<td>Reset Key</td>
</tr>
<tr>
<td>Housing Material</td>
<td>Flame-Retardant ABS</td>
</tr>
<tr>
<td>Colour</td>
<td>Red</td>
</tr>
<tr>
<td>Application</td>
<td>Indoor Use</td>
</tr>
<tr>
<td>Standard</td>
<td>EN54</td>
</tr>
</tbody>
</table>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Commercial Buildings</li>
<li>Shopping Centres</li>
<li>Industrial Facilities</li>
<li>Hotels &amp; Apartments</li>
<li>Educational Institutions</li>
<li>Hospitals &amp; Healthcare Facilities</li>
<li>Residential Complexes</li>
<li>Warehouses</li>
<li>Office Buildings</li>
<li>Public Facilities</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-manual-call-point/">Conventional Manual Call Point</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Strobe Sounder</title>
		<link>https://www.cityfireservice.com/products/conventional-strobe-sounder/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-strobe-sounder</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 09:42:01 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7966</guid>

					<description><![CDATA[<p>The AW-CSS2166-2 is a conventional fire alarm sounder strobe providing combined audible and visual warning signals.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-strobe-sounder/">Conventional Strobe Sounder</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 data-start="1179" data-end="1229"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50a.png" alt="🔊" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Conventional Sounder Strobe – AW-CSS2166-2</h4>
<p data-start="1230" data-end="1305"><em data-start="1230" data-end="1305">(Compatible with AW-CFP2166 Series Conventional Fire Alarm Control Panel)</em></p>
<div class="relative overflow-hidden transition-[max-height,opacity] duration-300 ease-out mt-1 mb-5 [&amp;:not(:first-child)]:mt-4" aria-hidden="false">
<div class="no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44">
<h6 class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl">Product Overview</h6>
<h6 class="border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)/3)] rounded-s-xl">The AW-CSS2166-2 is a conventional fire alarm sounder strobe providing combined audible and visual warning signals.</h6>
</div>
</div>
<p data-start="1498" data-end="1690">With ≥85 dB alarm output and a 1 flash per second strobe, it ensures clear notification across protected areas. It integrates seamlessly with AW-CFP2166 conventional fire alarm control panels.</p>
<p data-start="1692" data-end="1712"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</p>
<ul data-start="1713" data-end="1874">
<li data-start="1713" data-end="1750">
<p data-start="1715" data-end="1750"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Combined Audible &amp; Visual Alarm</p>
</li>
<li data-start="1751" data-end="1773">
<p data-start="1753" data-end="1773"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Alarm SPL ≥85 dB</p>
</li>
<li data-start="1774" data-end="1797">
<p data-start="1776" data-end="1797"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Flash Rate: 1/sec</p>
</li>
<li data-start="1798" data-end="1832">
<p data-start="1800" data-end="1832"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low Power Consumption ≤60 mA</p>
</li>
<li data-start="1833" data-end="1874">
<p data-start="1835" data-end="1874"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Compact, Durable ABS Housing (IP30)</p>
</li>
</ul>
<h5 data-start="1876" data-end="1909"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Specifications</h5>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1911" data-end="2174">
<thead data-start="1911" data-end="1940">
<tr data-start="1911" data-end="1940">
<th class="" data-start="1911" data-end="1923" data-col-size="sm">Parameter</th>
<th class="" data-start="1923" data-end="1940" data-col-size="sm">Specification</th>
</tr>
</thead>
<tbody data-start="1971" data-end="2174">
<tr data-start="1971" data-end="2003">
<td data-start="1971" data-end="1991" data-col-size="sm">Operating Voltage</td>
<td data-col-size="sm" data-start="1991" data-end="2003">Zone 24V</td>
</tr>
<tr data-start="2004" data-end="2034">
<td data-start="2004" data-end="2024" data-col-size="sm">Operating Current</td>
<td data-col-size="sm" data-start="2024" data-end="2034">≤60 mA</td>
</tr>
<tr data-start="2035" data-end="2068">
<td data-start="2035" data-end="2058" data-col-size="sm">Sound Pressure Level</td>
<td data-col-size="sm" data-start="2058" data-end="2068">≥85 dB</td>
</tr>
<tr data-start="2069" data-end="2096">
<td data-start="2069" data-end="2087" data-col-size="sm">Flash Frequency</td>
<td data-col-size="sm" data-start="2087" data-end="2096">1/sec</td>
</tr>
<tr data-start="2097" data-end="2137">
<td data-start="2097" data-end="2121" data-col-size="sm">Operating Temperature</td>
<td data-col-size="sm" data-start="2121" data-end="2137">-5°C to 40°C</td>
</tr>
<tr data-start="2138" data-end="2174">
<td data-start="2138" data-end="2151" data-col-size="sm">Dimensions</td>
<td data-col-size="sm" data-start="2151" data-end="2174">154 × 115 × 50.5 mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<h5 data-start="2181" data-end="2209"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Typical Applications</h5>
<p data-start="2211" data-end="2405"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Office Buildings<br data-start="2230" data-end="2233" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e8.png" alt="🏨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hotels &amp; Apartments<br data-start="2255" data-end="2258" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Centers &amp; Malls<br data-start="2285" data-end="2288" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Facilities<br data-start="2312" data-end="2315" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Universities<br data-start="2340" data-end="2343" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e5.png" alt="🏥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hospitals &amp; Healthcare Centers<br data-start="2376" data-end="2379" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Complexes</p>
<p data-start="2211" data-end="2405"><img fetchpriority="high" decoding="async" class="" src="https://www.cityfireservice.com/wp-content/uploads/2021/01/2292d887cc.jpg" width="333" height="378" /></p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-strobe-sounder/">Conventional Strobe Sounder</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Beam Detector Refletive</title>
		<link>https://www.cityfireservice.com/products/conventional-beam-detector-refletive/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-beam-detector-refletive</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 01 Aug 2026 09:34:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7965</guid>

					<description><![CDATA[<p>The AW-D130C Reflective Optical Beam Smoke Detector is designed for conventional fire alarm control systems and is LPCB Approved. It incorporates high-precision symmetrical infrared laser technology, ensuring stable performance, long-range detection, and dependable fire protection.</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-beam-detector-refletive/">Conventional Beam Detector Refletive</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Reflective Optical Beam Smoke Detector – AW-D130C</h3>
<h4>Conventional Fire Alarm Control System (LPCB Approved)</h4>
<p class="isSelectedEnd">The <strong>AW-D130C Reflective Optical Beam Smoke Detector</strong> is designed for <strong>conventional fire alarm control systems</strong> and is <strong>LPCB Approved</strong>. It incorporates high-precision symmetrical infrared laser technology, ensuring stable performance, long-range detection, and dependable fire protection.</p>
<p class="isSelectedEnd">Its practical housing design offers flexible terminal connections for easy installation and seamless integration with compatible conventional fire alarm control panels.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Product Overview</h4>
<p class="isSelectedEnd">The detector continuously transmits an infrared beam to a prism reflector and monitors the returned signal. When smoke interrupts the beam beyond the preset alarm threshold, an alarm condition is activated.</p>
<p class="isSelectedEnd">The AW-D130C is ideally suited for <strong>large indoor open areas</strong>, providing early smoke detection while minimizing the number of detectors required.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Key Features</h4>
<ul data-spread="false">
<li>Conventional fire alarm system compatibility</li>
<li>LPCB Approved</li>
<li>Built-in isolation function</li>
<li>Infrared remote control operation</li>
<li>High-precision symmetrical infrared laser</li>
<li>Reliable long-distance smoke detection</li>
<li>Suitable for warehouses and open indoor spaces</li>
<li>EN54-12 compliant</li>
<li>Detection distance: <strong>5–160 meters</strong></li>
<li>Easy alignment and maintenance</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
<tr>
<td>System Type</td>
<td>Conventional</td>
</tr>
<tr>
<td>Main Voltage</td>
<td>LOOP 24V or DC 12–24V</td>
</tr>
<tr>
<td>Working Current</td>
<td>Static ≤10mA @ DC 24V</td>
</tr>
<tr>
<td>Alarm Current</td>
<td>≤15mA @ DC 24V</td>
</tr>
<tr>
<td>Laser Concentricity</td>
<td>≤1° @ 160m</td>
</tr>
<tr>
<td>Detection Distance</td>
<td>5–160 m</td>
</tr>
<tr>
<td>Dimensions</td>
<td>184.3 × 143.3 × 120 mm</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>-10°C to +50°C</td>
</tr>
<tr>
<td>Relative Humidity</td>
<td>≤95% RH (Non-condensing)</td>
</tr>
<tr>
<td>Standard</td>
<td>EN54-12</td>
</tr>
<tr>
<td>Approval</td>
<td>LPCB Approved</td>
</tr>
</tbody>
</table>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Warehouses</li>
<li>Industrial Buildings</li>
<li>Logistics Centers</li>
<li>Aircraft Hangars</li>
<li>Shopping Centers</li>
<li>Exhibition Halls</li>
<li>Power Plants</li>
<li>Sports Facilities</li>
<li>Large Commercial Buildings</li>
<li>High Ceiling Structures</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Advantages</h4>
<ul data-spread="false">
<li>Early smoke detection over long distances</li>
<li>Reduced installation cost compared with multiple point detectors</li>
<li>Simple installation and maintenance</li>
<li>Stable performance in large open environments</li>
<li>Reliable fire protection for critical facilities</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-beam-detector-refletive/">Conventional Beam Detector Refletive</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Fire Alarm Devices Ziton</title>
		<link>https://www.cityfireservice.com/products/conventional-smoke-detector-ziton-z630-1/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-smoke-detector-ziton-z630-1</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 14 Jul 2026 07:03:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7797</guid>

					<description><![CDATA[<p>Ziton Conventional Fire Alarm Devices Reliable Fire Detection Solutions Ziton offers a range of high-quality fire detection devices engineered to provide reliable and early fire detection for commercial, industrial, educational, healthcare, and residential applications. Designed to comply with international fire&#8230;</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-detector-ziton-z630-1/">Conventional Fire Alarm Devices Ziton</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Ziton Conventional Fire Alarm Devices</h3>
<h4>Reliable Fire Detection Solutions</h4>
<p class="isSelectedEnd">Ziton offers a range of high-quality fire detection devices engineered to provide reliable and early fire detection for commercial, industrial, educational, healthcare, and residential applications. Designed to comply with international fire safety standards, Ziton detectors deliver dependable performance, easy installation, and long-term operational reliability for conventional fire alarm systems.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Product</h4>
<h4>Z630-1 Optical Smoke Detector</h4>
<p class="isSelectedEnd">The <strong>Ziton Z630-1</strong> is a conventional <strong>photoelectric (optical) smoke detector</strong> designed to provide early detection of slow-burning and smouldering fires. Utilizing advanced light-scatter optical sensing technology, it offers high sensitivity, excellent stability, and dependable performance in a wide range of commercial and industrial fire alarm applications. It is particularly suitable for environments with air conditioning and modern building interiors.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Key Features</h4>
<ul data-spread="false">
<li>Advanced Photoelectric (Optical) Smoke Detection</li>
<li>Early Response to Slow-Burning &amp; Smouldering Fires</li>
<li>EN54 Part 7 Certified</li>
<li>Low Profile Modern Design</li>
<li>High Immunity to Air Movement</li>
<li>Reliable Alarm LED Indication</li>
<li>Plug-in Detector Base</li>
<li>Simple Installation &amp; Maintenance</li>
<li>Long-Term Operational Stability</li>
<li>Compatible with Ziton Conventional Fire Alarm Systems</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Technical Specifications</h4>
<table>
<tbody>
<tr>
<th>Description</th>
<th>Specification</th>
</tr>
<tr>
<td>Model</td>
<td>Z630-1</td>
</tr>
<tr>
<td>Device Type</td>
<td>Conventional Optical Smoke Detector</td>
</tr>
<tr>
<td>Detection Principle</td>
<td>Photoelectric Light Scatter</td>
</tr>
<tr>
<td>Standard</td>
<td>EN54 Part 7</td>
</tr>
<tr>
<td>Operating Voltage</td>
<td>15–30 VDC</td>
</tr>
<tr>
<td>Wiring</td>
<td>2-Wire Conventional Zone</td>
</tr>
<tr>
<td>Coverage Area</td>
<td>Up to 100 m²*</td>
</tr>
<tr>
<td>Alarm Indication</td>
<td>Red LED</td>
</tr>
<tr>
<td>Ingress Protection</td>
<td>IP32</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>-20°C to +60°C</td>
</tr>
<tr>
<td>Relative Humidity</td>
<td>20–95% RH (Non-Condensing)</td>
</tr>
<tr>
<td>Mounting</td>
<td>Surface or Recessed Base</td>
</tr>
<tr>
<td>Colour</td>
<td>White</td>
</tr>
</tbody>
</table>
<p class="isSelectedEnd">*Coverage subject to local fire codes and installation standards.</p>
<div contenteditable="false">
<hr />
</div>
<h4>Typical Applications</h4>
<ul data-spread="false">
<li>Commercial Buildings</li>
<li>Office Complexes</li>
<li>Hotels</li>
<li>Hospitals</li>
<li>Schools &amp; Universities</li>
<li>Shopping Malls</li>
<li>Warehouses</li>
<li>Industrial Facilities</li>
<li>Residential Buildings</li>
</ul>
<div contenteditable="false">
<hr />
</div>
<h4>Benefits</h4>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fast &amp; Reliable Smoke Detection</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Excellent Performance for Smouldering Fires</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Easy Installation &amp; Maintenance</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Low False Alarm Rate</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> EN54 Approved Design</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Durable &amp; Reliable Construction</p>
<p class="isSelectedEnd"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2714.png" alt="✔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Ideal for Conventional Fire Alarm Systems</p>
<div contenteditable="false">
<hr />
</div>
<h4>City Fire &amp; Safety Services (Pvt) Ltd</h4>
<p class="isSelectedEnd">Supply • Installation • Testing • Commissioning • Maintenance of Fire Alarm &amp; Fire Protection Systems</p>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-smoke-detector-ziton-z630-1/">Conventional Fire Alarm Devices Ziton</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Conventional Fire Alarm Panel</title>
		<link>https://www.cityfireservice.com/products/conventional-fire-alarm-panel/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=conventional-fire-alarm-panel</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 02 Jul 2026 16:05:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7738</guid>

					<description><![CDATA[<div class="prodetacr_name">2, 4,8 &#38; 16 Zone Fire Alarm Conventional Panel The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2＆4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke.</div>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-fire-alarm-panel/">Conventional Fire Alarm Panel</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 data-start="163" data-end="209"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f5a5.png" alt="🖥" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Asenware Conventional Fire Alarm Panel</h4>
<h6 data-start="210" data-end="244">Model: <strong data-start="221" data-end="242">AW-CFP2166 Series</strong></h6>
<p>Reliable, EN54-Compliant Fire Alarm Control Solution</p>
<hr data-start="305" data-end="308" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f50e.png" alt="🔎" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Product Overview</strong></p>
<p data-start="336" data-end="611">The AW-CFP2166 Series Conventional Fire Alarm Panel is designed in compliance with EN54 Part 2 &amp; 4 standards. It is the central control unit of a conventional fire alarm system, managing smoke detectors, manual call points, bells, and sprinkler supervision.</p>
<p data-start="613" data-end="757">With flexible configuration from 4 zones up to 16 zones, the AW-CFP2166 is suitable for both small-scale and large-scale applications.</p>
<hr data-start="759" data-end="762" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Key Features</strong></p>
<ul data-start="785" data-end="1579">
<li data-start="785" data-end="867">
<p data-start="787" data-end="867"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> EN54 Part 2 &amp; 4 Certified – Ensures international fire safety compliance</p>
</li>
<li data-start="868" data-end="940">
<p data-start="870" data-end="940"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Scalable Zones – 1–8 zones standard, expandable up to 16 zones</p>
</li>
<li data-start="941" data-end="1021">
<p data-start="943" data-end="1021"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Zone Disablement – Individual zones can be disabled via button control</p>
</li>
<li data-start="1022" data-end="1338">
<p data-start="1024" data-end="1063"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Multiple Indications &amp; Outputs:</p>
<ul data-start="1067" data-end="1338">
<li data-start="1067" data-end="1123">
<p data-start="1069" data-end="1123"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f534.png" alt="🔴" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Fire Alarm Indication – Red FIRE LED on alarm</p>
</li>
<li data-start="1127" data-end="1202">
<p data-start="1129" data-end="1202"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f514.png" alt="🔔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Sounder / Fire Protection / Fire Routing / Fault Routing Outputs</p>
</li>
<li data-start="1206" data-end="1271">
<p data-start="1208" data-end="1271"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f7e1.png" alt="🟡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> General Fault Indication – Lights up for system errors</p>
</li>
<li data-start="1275" data-end="1338">
<p data-start="1277" data-end="1338"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/26a1.png" alt="⚡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Mains, Battery, Earth, Fuse &amp; System Fault Monitoring</p>
</li>
</ul>
</li>
<li data-start="1339" data-end="1413">
<p data-start="1341" data-end="1413"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Operational Control Buttons – Test, Reset, Evacuate, Silence</p>
</li>
<li data-start="1414" data-end="1497">
<p data-start="1416" data-end="1497"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Clear LED Display – Provides real-time system status and fault indication</p>
</li>
<li data-start="1498" data-end="1579">
<p data-start="1500" data-end="1579"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> User-Friendly Maintenance – Simple troubleshooting with LED diagnostics</p>
</li>
</ul>
<hr data-start="1581" data-end="1584" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Technical Parameters</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1617" data-end="2148">
<thead data-start="1617" data-end="1646">
<tr data-start="1617" data-end="1646">
<th data-start="1617" data-end="1629" data-col-size="sm">Parameter</th>
<th data-start="1629" data-end="1646" data-col-size="md">Specification</th>
</tr>
</thead>
<tbody data-start="1677" data-end="2148">
<tr data-start="1677" data-end="1707">
<td data-start="1677" data-end="1693" data-col-size="sm"><strong data-start="1679" data-end="1692">Model No.</strong></td>
<td data-start="1693" data-end="1707" data-col-size="md">AW-CFP2166</td>
</tr>
<tr data-start="1708" data-end="1743">
<td data-start="1708" data-end="1724" data-col-size="sm"><strong data-start="1710" data-end="1723">Standards</strong></td>
<td data-start="1724" data-end="1743" data-col-size="md">EN54-2 &amp; EN54-4</td>
</tr>
<tr data-start="1744" data-end="1783">
<td data-start="1744" data-end="1756" data-col-size="sm"><strong data-start="1746" data-end="1755">Zones</strong></td>
<td data-start="1756" data-end="1783" data-col-size="md">4 / 8 / 16 (expandable)</td>
</tr>
<tr data-start="1784" data-end="1858">
<td data-start="1784" data-end="1798" data-col-size="sm"><strong data-start="1786" data-end="1797">Outputs</strong></td>
<td data-start="1798" data-end="1858" data-col-size="md">Sounder / Fire Protection / Fire Routing / Fault Routing</td>
</tr>
<tr data-start="1859" data-end="1920">
<td data-start="1859" data-end="1881" data-col-size="sm"><strong data-start="1861" data-end="1880">Fault Detection</strong></td>
<td data-start="1881" data-end="1920" data-col-size="md">Mains, Battery, Earth, Fuse, System</td>
</tr>
<tr data-start="1921" data-end="1982">
<td data-start="1921" data-end="1945" data-col-size="sm"><strong data-start="1923" data-end="1944">Operation Buttons</strong></td>
<td data-start="1945" data-end="1982" data-col-size="md">Test / Reset / Evacuate / Silence</td>
</tr>
<tr data-start="1983" data-end="2028">
<td data-start="1983" data-end="1997" data-col-size="sm"><strong data-start="1985" data-end="1996">Display</strong></td>
<td data-start="1997" data-end="2028" data-col-size="md">Multi-LED status indicators</td>
</tr>
<tr data-start="2029" data-end="2079">
<td data-start="2029" data-end="2048" data-col-size="sm"><strong data-start="2031" data-end="2047">Power Supply</strong></td>
<td data-start="2048" data-end="2079" data-col-size="md">AC mains + Backup batteries</td>
</tr>
<tr data-start="2080" data-end="2148">
<td data-start="2080" data-end="2099" data-col-size="sm"><strong data-start="2082" data-end="2098">Applications</strong></td>
<td data-start="2099" data-end="2148" data-col-size="md">Commercial, Residential, Industrial buildings</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cc.png" alt="📌" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Applications</strong></p>
<p><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e2.png" alt="🏢" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Office Complexes<br data-start="2200" data-end="2203" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e8.png" alt="🏨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Hotels &amp; Hospitality<br data-start="2230" data-end="2233" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ec.png" alt="🏬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shopping Malls &amp; Warehouses<br data-start="2267" data-end="2270" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Industrial Facilities<br data-start="2298" data-end="2301" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3e0.png" alt="🏠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Residential Buildings<br data-start="2329" data-end="2332" /><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f393.png" alt="🎓" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Schools &amp; Institutions</p>
<hr data-start="2365" data-end="2368" />
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4e6.png" alt="📦" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Available Configurations &amp; Price Inquiry</strong></p>
<p data-start="2421" data-end="2506">We can provide the <strong data-start="2440" data-end="2471">AW-CFP2166 Fire Alarm Panel</strong> in the following configurations:</p>
<ul data-start="2508" data-end="2580">
<li data-start="2508" data-end="2531">
<p data-start="2510" data-end="2531"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 2-Zone Panel</p>
</li>
<li><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 4-Zone Panel</li>
<li data-start="2532" data-end="2555">
<p data-start="2534" data-end="2555"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 8-Zone Panel</p>
</li>
<li data-start="2556" data-end="2580">
<p data-start="2558" data-end="2580"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f539.png" alt="🔹" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 16-Zone Panel</p>
</li>
</ul>
<p>The post <a href="https://www.cityfireservice.com/products/conventional-fire-alarm-panel/">Conventional Fire Alarm Panel</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Standalone CO Detector</title>
		<link>https://www.cityfireservice.com/products/co-detector-standalone/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=co-detector-standalone</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 24 Jun 2026 08:08:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.cityfireservice.com/?post_type=product&#038;p=7682</guid>

					<description><![CDATA[<p>Detects hazardous carbon monoxide gas and provides immediate audible and visual warning to help protect occupants from CO poisoning.</p>
<p>The post <a href="https://www.cityfireservice.com/products/co-detector-standalone/">Standalone CO Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="PDq2pG_selectionAnchorContainer" data-section-id="10j5sdl" data-start="0" data-end="39">TUV Approved Standalone CO Detector</h3>
<p data-start="41" data-end="440">The <strong data-start="45" data-end="102">TUV Approved Standalone Carbon Monoxide (CO) Detector</strong> is a reliable life-safety device designed to continuously monitor carbon monoxide levels and provide early warning of dangerous CO gas accumulation. Featuring an advanced electrochemical sensing element, audible alarm, and visual indicators, it offers dependable protection for residential, commercial, and light industrial applications.</p>
<h4 data-start="442" data-end="459">Key Features</h4>
<ul data-start="460" data-end="817">
<li data-section-id="w3xxqc" data-start="460" data-end="513"><strong data-start="462" data-end="479">TUV Certified</strong> for safety and quality compliance</li>
<li data-section-id="cnaehx" data-start="514" data-end="556">High-precision electrochemical CO sensor</li>
<li data-section-id="19upyh1" data-start="557" data-end="599">Standalone operation with built-in alarm</li>
<li data-section-id="riiztu" data-start="600" data-end="641">Loud audible warning (typically ≥85 dB)</li>
<li data-section-id="jzd4sb" data-start="642" data-end="675">LED status and alarm indicators</li>
<li data-section-id="1p2ozsy" data-start="676" data-end="724">Self-diagnostic and fault monitoring functions</li>
<li data-section-id="etmj2z" data-start="725" data-end="746">Low battery warning</li>
<li data-section-id="1qn828i" data-start="747" data-end="782">Easy wall or ceiling installation</li>
<li data-section-id="nr3i" data-start="783" data-end="817">Continuous 24-hour CO monitoring</li>
</ul>
<h4 data-start="819" data-end="836">Applications</h4>
<ul data-start="837" data-end="1025">
<li data-section-id="7icdvj" data-start="837" data-end="860">Residential Buildings</li>
<li data-section-id="1qsvyqh" data-start="861" data-end="884">Apartments and Villas</li>
<li data-section-id="3wnxf1" data-start="885" data-end="910">Hotels and Guest Houses</li>
<li data-section-id="1kqi3t5" data-start="911" data-end="945">Offices and Commercial Buildings</li>
<li data-section-id="klfwlz" data-start="946" data-end="963">Generator Rooms</li>
<li data-section-id="zf1ykb" data-start="964" data-end="978">Boiler Rooms</li>
<li data-section-id="yxvg8y" data-start="979" data-end="1007">Kitchens and Utility Areas</li>
<li data-section-id="sz6m3o" data-start="1008" data-end="1025">Parking Garages</li>
</ul>
<p data-start="1027" data-end="1173"><strong data-start="1027" data-end="1040">Function:</strong> Detects hazardous carbon monoxide gas and provides immediate audible and visual warning to help protect occupants from CO poisoning.</p>
<p data-start="1175" data-end="1313" data-is-last-node="" data-is-only-node=""><strong data-start="1175" data-end="1193">Certification:</strong> TUV Approved<br data-start="1206" data-end="1209" /><strong data-start="1209" data-end="1218">Type:</strong> Standalone Carbon Monoxide Detector<br data-start="1254" data-end="1257" /><strong data-start="1257" data-end="1279">Country of Origin:</strong> China</p>
<p>The post <a href="https://www.cityfireservice.com/products/co-detector-standalone/">Standalone CO Detector</a> appeared first on <a href="https://www.cityfireservice.com">Fire Fighting Equipment | Fire Safety Equipment</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>